32
Workstation Board Installations and Upgrades
Replacing the Backup Battery
The lithium battery on the Workstation board powers the RTC for up to 10 years in the absence of
power. When the battery starts to weaken, it loses voltage, and the Workstation settings stored
in CMOS RAM in the RTC (for example, the date and time) may be wrong. Contact your customer
service representative or dealer for a list of approved devices.
WARNING
Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type
recommended by the equipment manufacturer. Discard used batteries according to manufacturer’s
instructions.
1. Observe the safety and ESD precautions at the beginning of this chapter.
2. Open the chassis.
3. Insert the tip of a small flat-bladed screwdriver, or an equivalent, under the tab in the plastic
retainer. Gently push down on the screwdriver to lift the battery.
4. Remove the battery from its socket.
Figure 5. Replacing the Backup Battery
5. Dispose of the battery according to local ordinance.
6. Remove the new lithium battery from its package and, being careful to observe the correct
polarity, insert it in the battery socket.
7. Close the chassis.
8. Run BIOS Setup to restore the configuration settings to the RTC.
Summary of Contents for Workstation Fusion 7000
Page 1: ...User s Manual MAXDATA Workstation Fusion 7000 ...
Page 2: ...2 Contents ...
Page 6: ...6 Contents ...
Page 22: ...22 Features ...
Page 42: ...42 Solving Problems ...