26
Configuration Software and Utilities
Hardware Monitoring
The mainboard has an integrated Winbond Heceta 836327HF chip that is responsible for hardware
monitoring. Together, the Winbond Heceta chip and the Intel
®
LanDesk
™
Client Manager (LDCM) 6
software provide basic Workstation hardware monitoring that alerts a system administrator if a hard-
ware problem occurs.
The LDCM software is for use with Windows
®
2000 Workstation and Windows
®
2000 Advanced
Workstation operating systems. Other operating systems supported by the mainboard, such as
NetWare 6.0 or Red Hat Linux, will not be monitored with LDCM. Table 8 lists the monitored headers
and sensors on the mainboard.
Table 8. Monitored Headers and Sensors
Sensor Type
Item
Description
Voltage
CPU1/2
Monitors processor voltage (one CPU power plane)
1.8 V
Chipset
VCC3
Monitors VCC3
VCC
Monitors VCC
+12 V
Mo12 V
2.5 V
Monitors 2.5 V (for DIMM)
Vbat
Battery pin voltage
5 VSB
Monitors 5 VSB (5 V stand-by)
Fan Speed
CPU1_FAN
Monitors primary processor fan speed
CPU2_FAN
Monitors secondary processor fan speed
CHASSIS_FAN
Monitors chassis fan speed through chassis fan
header 3 only. (Total 4 chassis fans available)
Temperature
CPU1
Monitors primary processor temperature
CPU2
Monitors secondary processor temperature
CHASSIS
Monitors chassis ambient temperature
Serial ATA RAID BIOS Configuration
NOTE
To use the SATA RAID option, two SATA hard disk drives are required.
Serial ATA on the mainboard is set to Base ATA mode by default. It must be changed to RAID mode
before the RAID Configuration Utility can be used to configure Serial ATA RAID drives.
Follow the instructions that come with this utility to change to RAID mode.
Summary of Contents for Workstation Fusion 7000
Page 1: ...User s Manual MAXDATA Workstation Fusion 7000 ...
Page 2: ...2 Contents ...
Page 6: ...6 Contents ...
Page 22: ...22 Features ...
Page 42: ...42 Solving Problems ...