4-4
INSTALLATION
www.maxcessintl.com
MAGPOWR TLC-B
MI 850A356 1 A
Flange mounting
The TLC-B Load Cell can be mounted using one of two bolt
patterns:
3-hole on a
150 mm bolt circle
4-hole on a
135 mm bolt circle
Before installation, each machine frame must be prepared with a
100 mm hole for the load cell hub and M8x1 (or 5/16")
threaded holes for the fasteners.
Use M8 or 5/16" bolts to mount the load cell to vertical machine
frames. Minimum fastener length is 70 mm [2.75 inches].
See page 3-2 for maximum roller diameters when mounting
inside the machine frame.