4-3
INSTALLATION
www.maxcessintl.com
MAGPOWR TLC-B
MI 850A356 1 A
Resultant force
polarity
The label on the load cell indicates the output polarity based on
the resultant force direction in relation to the connector.
Default wiring
Cable wiring diagram
+ Power
Pin 1 (A)
Red
+ Signal
Pin 2 (B)
White
- Signal
Pin 3 (C)
Black
- Power
Pin 4 (D)
Green
When the resultant force is pointing
away from the connector the output
voltage is positive (+).
When the resultant force
is pointing toward the connector
the output voltage is negative (-).
Polarity auto-sensing
MAGPOWR readout devices and tension controllers with the
polarity auto-sensing feature automatically sense output polarity
regardless of the load cell orientation. Refer to your product
manual to determine whether your device has auto-sensing.
If your device does not support polarity auto-sensing, you will
need to manually reverse the polarity if the resultant force is
pointing toward the connector (output voltage is negative).
Exchange the (-S) and the (+S) wires at the device terminal block.