MAINTENANCE
7 - 1
DSE-17
www.maxcess.eu
MI 1064 1 C
Wa
rtu
ng.fm
7 MAINTENANCE
WARNING:
Danger of injury by crushing.
Maintenance work must only be performed on the sensor
when the power is turned off and the machine is stopped and
protected against being turned on again.
Maintenance
Cleaning
Ambient dust and dirt must be cleaned from the protection
panes at regular intervals using a neutral synthetic cleaning
agent and a soft cloth. Make certain the cleaner is suitable for
PMMA plastics.
Recalibration of the sensor
If the protection panes begin to show signs of wear, the accuracy
of the sensor can be improved by adjusting the brightness
values of the sensor to the changed conditions with a new
calibration.
Calibrating sensor DSE-17, page 5-2
No other maintenance work is required for the sensor.
Decommissioning
1. Turn off the electrical power to the system.
2. Disconnect the signal cable from the sensor.
3. Unscrew the sensor from its bracket.
4. Store the sensor in a cool, clean and dry place.
OR
Dispose of the sensor according to your national
requirements.