background image

18

11. (Fig.D) Open the drain cock to discharge 

all the compressed air and water in the air 
tank.

If you found any abnormalities in the check-
up or inspection prior to the operation, send 
the machine to your dealer or authorized 
service facility for inspection or repair.

Operating Procedure

Before operating the machine, be sure to carry 
out the "Inspection and checkup prior to opera-
tion" described on page 17.

1. Fully open the drain cock and turn the 

power switch on. The buzzer will sound 
with a beep at the same time.

For buzzer sounding patterns, see 
page 20.
After the operation has started, close the 
drain cock tight to increase the pressure.

2. (Fig.I) After confirming the operation has 

stopped due to the increased pressure, 
turn the adjustment handle of the pres-
sure-reduction valve to adjust the operat-
ing pressure of the nailer and pneumatic 
tool to the appropriate level. When ad-
justing the pressure, turn the pressure-
reduction valve's adjustment handle 
counterclockwise to set the pressure at a 
level lower than the appropriate value by 
2 bars once. Then proceed to the adjust-
ment while increasing the pressure by 
turning the handle clockwise.

Make sure to start the adjustment at a level 
lower than the appropriate pressure and 
continue the adjustment while increasing 
the pressure from that level upward. If you 
start the adjustment from a level higher 
than the appropriate value, an error results 
between the pressure gauge value and ac-
tually used pressure. (Due to Characteris-
tics of pressure-reduction valve 
respectively)

2 pressure-reduction valves provided on 
this machine allow you to connect MAX 

 and the general-purpose nailer or 

pneumatic tool.
<Pressure-reduction valve H>   Allows 
connection and use of MAX PowerLite 
tools (of operating pressure of 24.5 bars 
(355psi) maximum)
<Pressure-reduction valve L>   Allows con-
nection and use of the general-purpose 
nailers or pneumatic tools (of operating 
pressure of 8.3 bars (120psi) maximum)

You must observe the specified operating 
air pressure for the nailers and pneumatic 
tools.
Using a nailer or pneumatic tool without ad-
justing the supply pressure with the reduc-
tion valve can seriously degrade their 
performance, induce their premature aging 
or damage them.

Using a nailer or pneumatic tool at an inappro-
priate pressure level (at an unnecessary high 
pressure) increases their air consumption, po-
tentially degrading their capability in continu-
ous work. Be sure to use them at the 
appropriate pressure.

3. (Fig.J) After you have finished with the 

adjustment of supply pressure, you can 
start the operation by connecting the air 
hose to the air outlet (air chuck).

4. Connect the high pressure hose to the 

high pressure air hose for MAX PowerLite 
tools to the high pressure air chuck on 
the H side of the pressure-reduction 
valve.

Connect the air hose for the general-purpose 
nailer to the air chuck on the L side of the 
pressure-reduction valve.

The air chuck is the one-touch type, allow-
ing you to connect the air plug to the air 
chuck just by pushing in.

Before connecting the air hose to this com-
pressor, make sure that the air hose and 
hose fixture are firmly secured.

WARNING

WARNING

Summary of Contents for AKHL1260E Powerlite

Page 1: ...L ET LES CONSIGNES DE S CURIT AFIN DE GARANTIR UN FONCTIONNEMENT S R CONSERVER CE MANUEL EN LIEU S R AVEC L OUTIL AFIN DE POUVOIR LE CONSULTER ULTERIEUREMENT ANTES DE UTILIZAR ESTE COMPRESOR LEA DETEN...

Page 2: ...e si no se evita puede resultar en muerte o lesiones graves PRECAUCI N Indica una situaci n potencialmente peligrosa que si no se evita puede resultar en una herida menor o moderada NOTA Destaca las i...

Page 3: ...3 Fig A Abb A 2 1 5 7 8 9 b c 0 a d 4 3 6 h e f g Fig B Abb B j k l m i 9...

Page 4: ...4 Fig C Abb C Fig D Abb D Fig E Abb E Fig F Abb F Fig G Abb G Fig H Abb H Fig I Abb I Fig J Abb J Fig K Abb K Fig L Abb L...

Page 5: ...5 Fig M Abb M Fig N Abb N Fig O Abb O Fig P Abb P Fig Q Abb Q Fig R Abb R Fig S Abb S Fig T Abb T Fig U Abb U...

Page 6: ...6...

Page 7: ...WARNINGS AND ALL IN STRUCTIONS Failure to follow the warnings and instructions may result in death serious injury Save all warn ings and instructions for future reference RISK OF ELECTRIC SHOCK WARNIN...

Page 8: ...y for EU countries Do not dispose of electric equipment together with household waste materi al In observance of European Directive 2012 19 EU on waste electrical and electronic equipment and its impl...

Page 9: ...ower switch in the OFF position before connecting the compressor to its power source 7 STORE COMPRESSOR PROPERLY When not in use the compressor should be stored in dry place Keep out of reach of chil...

Page 10: ...18 KEEP ALL SCREWS BOLTS AND COV ERS TIGHTLY IN PLACE Keep all screws bolts and plates tightly mounted Check their conditions periodically 19 KEEP HANDLES DRY CLEAN AND FREE FROM OIL AND GREASE Slippe...

Page 11: ...RECT CURRENT POWER SUPPLY The compressor will break or be damaged from burning 34 THIS COMPRESSOR IS FOR INDOOR USE DO NOT INSTALL THE COMPRES SOR IN ANY PLACE EXPOSED TO RAIN OR SPLASHED WATER HIGH H...

Page 12: ...sk of electric shock 3 SPECIFICATIONS Product No AKHL1260E EX CE AKHL1260E EX USA Dimensions L 583mm EX 583mm 23 EX 23 W 309mm EX 380mm 12 1 8 EX 15 H 337mm EX 479mm 13 1 4 EX 18 7 8 Weight 16 2kg EX...

Page 13: ...pped with a cord having a grounding wire with an appropriate grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordin...

Page 14: ...fire due to burnout or ignition 7 AVOIDING A PLACE EXPOSED TO HIGH TEMPERATURE OR THE DIRECT SUN SHINE BE SURE TO USE THE MACHINE IN THE WELL VENTILATED SHADE Using it under high temperature or in the...

Page 15: ...pressure on the pressure reduction valves REGULAR 8 3 bar 120psi maximum 7 High pressure air chuck for MAX tools It connects the MAX air hose for the tools 8 Regular pressure air chuck for regular pre...

Page 16: ...the noises accompanying the operation or when tripping of the circuit breaker is anticipated during continuous operation Press the Quiet mode switch to turn on this mode A buzzer sounds with a beep a...

Page 17: ...cannot move it anymore and make sure that the above operation moves the pressure gauge pointer Fig F at both locations As the pressure in the air tank increases due to the pressure characteristic of...

Page 18: ...Due to Characteris tics of pressure reduction valve respectively 2 pressure reduction valves provided on this machine allow you to connect MAX and the general purpose nailer or pneumatic tool Pressure...

Page 19: ...ems existing in the operating environment stop using the compressor and send it to your dealer or authorized service facility for checkups or repairs 6 ABNORMALITIES DURING OPERATION If you detect any...

Page 20: ...xcessively high or low voltage 2 Long blinking Long beep sounds Pii Pii Pii Motor temperature went abnormally high Temperature in the control circuit has built up to an abnormally high level Do not us...

Page 21: ...move the air tank by lifting up the compressor 5 Fig U Fasten the four screws with a screwdriver 6 Fig L C Plug the compressor s power cord in the electric outlet and turn the compressor s power switc...

Page 22: ...its performance Please do not hesitate to let your dealer or authorized service facility in spect your machine more than once a year 4 Handle this machine carefully Droppingthemachine inadvertently b...

Page 23: ...nos produits Las especificaciones y el dise o de los productos de este manual estar n sujetos a modificaci n sin previo aviso debido a nuestros continuos esfuerzos para mejorar la calidad de nuestros...