25. DO NOT MODIFY THE COMPRESSOR

Do not modify the compressor. Always con-
tact the authorized service facility for any re-
pairs. Unauthorized modification may not 
only impair the compressor performance but 
may also result in accident or injury to repair 
personnel who do not have the required 
knowledge and technical expertise to per-
form the repair operations correctly.

26. TURN OFF THE SWITCH WHEN THE 

COMPRESSOR IS NOT USED

When the compressor is not used, turn the 
switch OFF, disconnect the plug from the 
power source and open the drain cock to dis-
charge the compressed air from the air tank.

27. NEVER TOUCH THE SURFACE OF THE 

HIGH-TEMPERATURE SECTION

In order to prevent a burn, do not touch the 
piping, head, cylinder, motor, tank, inverter 
case and other metal parts.

28. DO NOT DIRECT AIR STREAM AT BODY

Risk of injury, do not direct compressed air at 
persons or animals.

29. DRAIN TANK

Drain tank daily.

30. DO NOT STOP COMPRESSOR BY PULL-

ING OUT THE PLUG

Use the "POWER" switch.

31. WHENEVER USING THE HIGH PRESSURE 

SIDE OF THE MAX POWERLITE COMPRES-
SOR, THE GENUINE PARTS FOR THE MAX 
POWERLITE TOOLS, POWERLITE HOSE  
MUST BE USED.

32. NEVER USE A TRANSFORMER FOR THE 

POWER SUPPLY OF THIS COMPRESSOR. 
USING A TRANSFORMER TO INCREASE THE 
VOLTAGE WILL CAUSE A FAILURE OR 
BURNOUT. (IF A TRANSFORMER IS USED, 
OPERATION OF THE MACHINE WILL STOP.) 

33. NEVER CONNECT THE COMPRESSOR 

TO AN ENGINE GENERATOR OR DI-
RECT-CURRENT POWER SUPPLY

The compressor will break or be damaged 
from burning.

34. THIS COMPRESSOR IS FOR INDOOR 

USE. DO NOT INSTALL THE COMPRES-
SOR IN ANY PLACE EXPOSED TO RAIN 
OR SPLASHED WATER, HIGH-HUMIDITY 
PLACE OR HIGH-TEMPERATURE PLACE

If used in the wet condition, it could produce 
an electric shock or be short-circuited, result-
ing in ignition.  Use it under the environmen-
tal conditions provided by its specifications. 
Also, do not store or use in cold environ-
ments.

35. DO NOT OPERATE THE TOOL NEAR A 

FLAMMABLE SUBSTANCE

Never operate the tool near a flammable 
substance (e.g., thinner, gasoline, etc.). Vol-
atile fumes from these substances could be 
drawn into the compressor and compressed 
together with the air and this could result in 
an explosion.

36. NEVER USE THE TOOL IN AN EXPLO-

SIVE ATMOSPHERE

Sparks from the tool may ignite atmospheric 
gases, dust or other combustible materials.

37. BE SURE TO EARTH THE COMPRESSOR

Earth the compressor to prevent a worker 
from getting an electric shock.  It comes with 
a 3-pole cord and a 3-pole earthing plug so 
that it can be connected to an appropriate 
earthing plug socket.
A green-and-yellow striped wire is an earth-
ing conductor.  Never connect it to other 
charged terminals. 

38. CARRY THE COMPRESSOR IN THE FOL-

LOWING PROPER MANNERS. 

AKHL1260E : Hold the com-
pressor grips with both 
hands. 

AKHL1260EX : 
Carry the compres-
sor by having two 
people hold each 
side of the com-
pressor grips.

Do not turn the compressor over or lift it with 
a hook or rope.

39. TAKE CARE TO TRANSPORT THE COM-

PRESSOR CORRECTLY, DO NOT OVER-
TURN IT OR LIFT IT WITH HOOKS OR 
ROPES.

Summary of Contents for AKHL1260E Powerlite

Page 1: ...L ET LES CONSIGNES DE S CURIT AFIN DE GARANTIR UN FONCTIONNEMENT S R CONSERVER CE MANUEL EN LIEU S R AVEC L OUTIL AFIN DE POUVOIR LE CONSULTER ULTERIEUREMENT ANTES DE UTILIZAR ESTE COMPRESOR LEA DETEN...

Page 2: ...e si no se evita puede resultar en muerte o lesiones graves PRECAUCI N Indica una situaci n potencialmente peligrosa que si no se evita puede resultar en una herida menor o moderada NOTA Destaca las i...

Page 3: ...3 Fig A Abb A 2 1 5 7 8 9 b c 0 a d 4 3 6 h e f g Fig B Abb B j k l m i 9...

Page 4: ...4 Fig C Abb C Fig D Abb D Fig E Abb E Fig F Abb F Fig G Abb G Fig H Abb H Fig I Abb I Fig J Abb J Fig K Abb K Fig L Abb L...

Page 5: ...5 Fig M Abb M Fig N Abb N Fig O Abb O Fig P Abb P Fig Q Abb Q Fig R Abb R Fig S Abb S Fig T Abb T Fig U Abb U...

Page 6: ...6...

Page 7: ...WARNINGS AND ALL IN STRUCTIONS Failure to follow the warnings and instructions may result in death serious injury Save all warn ings and instructions for future reference RISK OF ELECTRIC SHOCK WARNIN...

Page 8: ...y for EU countries Do not dispose of electric equipment together with household waste materi al In observance of European Directive 2012 19 EU on waste electrical and electronic equipment and its impl...

Page 9: ...ower switch in the OFF position before connecting the compressor to its power source 7 STORE COMPRESSOR PROPERLY When not in use the compressor should be stored in dry place Keep out of reach of chil...

Page 10: ...18 KEEP ALL SCREWS BOLTS AND COV ERS TIGHTLY IN PLACE Keep all screws bolts and plates tightly mounted Check their conditions periodically 19 KEEP HANDLES DRY CLEAN AND FREE FROM OIL AND GREASE Slippe...

Page 11: ...RECT CURRENT POWER SUPPLY The compressor will break or be damaged from burning 34 THIS COMPRESSOR IS FOR INDOOR USE DO NOT INSTALL THE COMPRES SOR IN ANY PLACE EXPOSED TO RAIN OR SPLASHED WATER HIGH H...

Page 12: ...sk of electric shock 3 SPECIFICATIONS Product No AKHL1260E EX CE AKHL1260E EX USA Dimensions L 583mm EX 583mm 23 EX 23 W 309mm EX 380mm 12 1 8 EX 15 H 337mm EX 479mm 13 1 4 EX 18 7 8 Weight 16 2kg EX...

Page 13: ...pped with a cord having a grounding wire with an appropriate grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordin...

Page 14: ...fire due to burnout or ignition 7 AVOIDING A PLACE EXPOSED TO HIGH TEMPERATURE OR THE DIRECT SUN SHINE BE SURE TO USE THE MACHINE IN THE WELL VENTILATED SHADE Using it under high temperature or in the...

Page 15: ...pressure on the pressure reduction valves REGULAR 8 3 bar 120psi maximum 7 High pressure air chuck for MAX tools It connects the MAX air hose for the tools 8 Regular pressure air chuck for regular pre...

Page 16: ...the noises accompanying the operation or when tripping of the circuit breaker is anticipated during continuous operation Press the Quiet mode switch to turn on this mode A buzzer sounds with a beep a...

Page 17: ...cannot move it anymore and make sure that the above operation moves the pressure gauge pointer Fig F at both locations As the pressure in the air tank increases due to the pressure characteristic of...

Page 18: ...Due to Characteris tics of pressure reduction valve respectively 2 pressure reduction valves provided on this machine allow you to connect MAX and the general purpose nailer or pneumatic tool Pressure...

Page 19: ...ems existing in the operating environment stop using the compressor and send it to your dealer or authorized service facility for checkups or repairs 6 ABNORMALITIES DURING OPERATION If you detect any...

Page 20: ...xcessively high or low voltage 2 Long blinking Long beep sounds Pii Pii Pii Motor temperature went abnormally high Temperature in the control circuit has built up to an abnormally high level Do not us...

Page 21: ...move the air tank by lifting up the compressor 5 Fig U Fasten the four screws with a screwdriver 6 Fig L C Plug the compressor s power cord in the electric outlet and turn the compressor s power switc...

Page 22: ...its performance Please do not hesitate to let your dealer or authorized service facility in spect your machine more than once a year 4 Handle this machine carefully Droppingthemachine inadvertently b...

Page 23: ...nos produits Las especificaciones y el dise o de los productos de este manual estar n sujetos a modificaci n sin previo aviso debido a nuestros continuos esfuerzos para mejorar la calidad de nuestros...