background image

13

4. INSTRUCTIONS FOR OP-

ERATION

Unpack the compressor and check for any defi-
ciency, damage caused during transportation 
and loose bolts and screws.

READ SECTION TITLED " SAFETY INSTRUC-
TIONS "
WEAR SAFETY GLASSES OR GOGGLES

Danger to the eyes always exists due to the possi-
bility of dust being blown up by the exhausted air or 
of a fastener flying up to the improper handling of 
the tool. For these reasons, safety glasses or gog-
gles shall always be worn when operating the tool. 
The employer and/or user must ensure that proper 
eye protection is worn. Eye protection equipment 
must conform to the requirements of  Council Di-
rective 89/686/EEC of 21 DEC. 1989 (the Ameri-
can National Standards Institute. ANSI Z87.1) and 
provide both frontal and side protection.

NOTE:

Non-side shielded spectacles and face 
shields alone do not provide adequate 
protection.

NOTE:

The information contained in this Instruc-
tion Manual is designed to assist you in 
the safe operation and maintenance of 
the compressor.
Some illustrations in this Instruction Manu-
al may show details or attachments that 
differ from those on your own compressor.

1. GROUNDING INSTRUCTIONS

1. THIS PRODUCT MUST BE GROUNDED

In the event of an electrical short circuit, 
grounding reduces the risk of electric shock 
by providing an escape wire for the electric 
current. This product is equipped with a cord 
having a grounding wire with an appropriate 
grounding plug. The plug must be plugged 
into an outlet that is properly installed and 
grounded in accordance with all local codes 
and ordinances.

2.

WARNING: IMPROPER INSTALLATION 

OF THE GROUNDING PLUG IS ABLE TO 
RESULT IN A RISK OF ELECTRIC SHOCK

When repair or replacement of the cord or 
plug is required, do not connect the ground-
ing wire to either power terminal. The wire 
with insulation having an outer surface that is 
green with or without yellow stripes is the 
grounding wire.

3. CHECK WITH A QUALIFIED ELECTRICIAN 

OR SERVICEMAN WHEN THE GROUND-
ING INSTRUCTIONS ARE NOT COM-
PLETELY UNDERSTOOD, OR WHEN IN 
DOUBT AS TO WHETHER THE PRODUCT 
IS PROPERLY GROUNDED. DO NOT MOD-
IFY THE PLUG PROVIDED; IF IT DOES NOT 
FIT THE OUTLET, HAVE THE PROPER 
OUTLET INSTALLED BY A QUALIFIED 
ELECTRICIAN.

4. CE MODEL IS FOR USE ON A NOMINAL 

230-V CIRCUIT, AND USA MODEL IS FOR 
USE ON A NOMINAL 120-V. EACH PROD-
UCT HAS GROUNDING PLUG. ONLY CON-
NECT THE PRODUCT TO AN OUTLET 
HAVING THE SAME CONFIGURATION AS 
THE PLUG. DO NOT USE AN ADAPTER 
WITH THIS PRODUCT.

2. INSTALLATION

1. NEVER USE THE MACHINE IN A PLACE 

WHERE ANY VOLATILE COMBUSTIBLE 
SUBSTANCE HAS BEEN STORED.

Never use it near gasoline, thinner, gas, 
paint or adhesive agent, because they could 
be ignited or blow up.

2. NEVER USE THE MACHINE NEAR THE 

HEAT OF FIRE OR ANY COMBUSTIBLE 
SUBSTANCE.

3. DO NOT USE THE MACHINE IN A OVERLY 

DUSTY(WOODEN CHIPS, ETC.) PLACE.

WARNING

Plug

Grounding Pin

Grounded 

Outlets

Grounding Pin

Plug

Grounded 

Outlets

WARNING

Summary of Contents for AKHL1260E Powerlite

Page 1: ...L ET LES CONSIGNES DE S CURIT AFIN DE GARANTIR UN FONCTIONNEMENT S R CONSERVER CE MANUEL EN LIEU S R AVEC L OUTIL AFIN DE POUVOIR LE CONSULTER ULTERIEUREMENT ANTES DE UTILIZAR ESTE COMPRESOR LEA DETEN...

Page 2: ...e si no se evita puede resultar en muerte o lesiones graves PRECAUCI N Indica una situaci n potencialmente peligrosa que si no se evita puede resultar en una herida menor o moderada NOTA Destaca las i...

Page 3: ...3 Fig A Abb A 2 1 5 7 8 9 b c 0 a d 4 3 6 h e f g Fig B Abb B j k l m i 9...

Page 4: ...4 Fig C Abb C Fig D Abb D Fig E Abb E Fig F Abb F Fig G Abb G Fig H Abb H Fig I Abb I Fig J Abb J Fig K Abb K Fig L Abb L...

Page 5: ...5 Fig M Abb M Fig N Abb N Fig O Abb O Fig P Abb P Fig Q Abb Q Fig R Abb R Fig S Abb S Fig T Abb T Fig U Abb U...

Page 6: ...6...

Page 7: ...WARNINGS AND ALL IN STRUCTIONS Failure to follow the warnings and instructions may result in death serious injury Save all warn ings and instructions for future reference RISK OF ELECTRIC SHOCK WARNIN...

Page 8: ...y for EU countries Do not dispose of electric equipment together with household waste materi al In observance of European Directive 2012 19 EU on waste electrical and electronic equipment and its impl...

Page 9: ...ower switch in the OFF position before connecting the compressor to its power source 7 STORE COMPRESSOR PROPERLY When not in use the compressor should be stored in dry place Keep out of reach of chil...

Page 10: ...18 KEEP ALL SCREWS BOLTS AND COV ERS TIGHTLY IN PLACE Keep all screws bolts and plates tightly mounted Check their conditions periodically 19 KEEP HANDLES DRY CLEAN AND FREE FROM OIL AND GREASE Slippe...

Page 11: ...RECT CURRENT POWER SUPPLY The compressor will break or be damaged from burning 34 THIS COMPRESSOR IS FOR INDOOR USE DO NOT INSTALL THE COMPRES SOR IN ANY PLACE EXPOSED TO RAIN OR SPLASHED WATER HIGH H...

Page 12: ...sk of electric shock 3 SPECIFICATIONS Product No AKHL1260E EX CE AKHL1260E EX USA Dimensions L 583mm EX 583mm 23 EX 23 W 309mm EX 380mm 12 1 8 EX 15 H 337mm EX 479mm 13 1 4 EX 18 7 8 Weight 16 2kg EX...

Page 13: ...pped with a cord having a grounding wire with an appropriate grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordin...

Page 14: ...fire due to burnout or ignition 7 AVOIDING A PLACE EXPOSED TO HIGH TEMPERATURE OR THE DIRECT SUN SHINE BE SURE TO USE THE MACHINE IN THE WELL VENTILATED SHADE Using it under high temperature or in the...

Page 15: ...pressure on the pressure reduction valves REGULAR 8 3 bar 120psi maximum 7 High pressure air chuck for MAX tools It connects the MAX air hose for the tools 8 Regular pressure air chuck for regular pre...

Page 16: ...the noises accompanying the operation or when tripping of the circuit breaker is anticipated during continuous operation Press the Quiet mode switch to turn on this mode A buzzer sounds with a beep a...

Page 17: ...cannot move it anymore and make sure that the above operation moves the pressure gauge pointer Fig F at both locations As the pressure in the air tank increases due to the pressure characteristic of...

Page 18: ...Due to Characteris tics of pressure reduction valve respectively 2 pressure reduction valves provided on this machine allow you to connect MAX and the general purpose nailer or pneumatic tool Pressure...

Page 19: ...ems existing in the operating environment stop using the compressor and send it to your dealer or authorized service facility for checkups or repairs 6 ABNORMALITIES DURING OPERATION If you detect any...

Page 20: ...xcessively high or low voltage 2 Long blinking Long beep sounds Pii Pii Pii Motor temperature went abnormally high Temperature in the control circuit has built up to an abnormally high level Do not us...

Page 21: ...move the air tank by lifting up the compressor 5 Fig U Fasten the four screws with a screwdriver 6 Fig L C Plug the compressor s power cord in the electric outlet and turn the compressor s power switc...

Page 22: ...its performance Please do not hesitate to let your dealer or authorized service facility in spect your machine more than once a year 4 Handle this machine carefully Droppingthemachine inadvertently b...

Page 23: ...nos produits Las especificaciones y el dise o de los productos de este manual estar n sujetos a modificaci n sin previo aviso debido a nuestros continuos esfuerzos para mejorar la calidad de nuestros...