MAX POWER
Closing adjustments (lock)
This is a correctly locked thruster
F
G
Maximum gap 0.01mm
Closing adjustments (closing plate)
Fig 1
Fig 2
Gap
Caution this situation would
cause damage to the turbine while
at sea .
This gap is essential it should be
of at least 5mm
In this situation there is still
up wards movement possible
A
! ! Rubber blocks to be removed
after closing plate ajustment,
but before locking bolt ajustment.
- 22 INSTALLATION MANUAL RETRACT R 450