G-Series User Manual Rev2020A
19
Specifications
G105 SPECIFICATIONS
Flow Range
75 cc/min to 105 liters/min
Accuracy (at 30 cP)
±
0.3% of reading over a 100:1 range
Maximum Operating Pressure 6000 psi (414 bar)
Weight
7.7 kg
Recommended Filtration
30 micron
Port Size(s)
3/4" NPT or #10 SAE
Fluids
Most non-aqueous, hydrocarbon based fluids
MATERIALS OF CONSTRUCTION
External
Stainless steel, type 303
Wetted
Stainless steel, type 303, 440C, 17-4
O-Rings
Standard, Viton
®
Optional: Teflon®, Perfluoroelastomer
FREQUENCY TRANSMITTER
Output Signal
Standard: 5 Vdc, single phase
Optional: Quadrature 5 Vdc, two phase
Current sinking, 20 mA max., single phase
K-Factor
Single Phase: 25 pulses/cc
Two Phase: 50 pulses/cc, 4x decoded
(12.5 pulses/cc/phase, 1x decoded)
Power Supply Requirements
5 - 26 Vdc, @ 30 mA
Ambient Operational Range
-40°C to 80°C, Single piece — Two piece to 110°C
Metered Liquid Temp Range
-40°C to 90°C, Standard model
(based on 20° ambient)
-40°C to 155°C, Two piece high temperature model
-40°C to 225°C, Two piece, ultra high temperature model
Compliance
CE Certified, Ex-proof version available with ATEX/IECEx II 2 G Ex db IIB Tx Gb as well
as UL, cUL certification for Class 1, Division 1, Groups C and D, Tx
ANALOG TRANSMITTER
Output Signal
Any range of
±
10V or
±
20mA Linearized and damped with anti-dither protection.
Power Supply Requirements
Two Models: 12Vdc @ 90 mA, 24Vdc @ 45 mA
Ambient Operational Range
-40°C to 80°C, Single piece — Two piece to 110°C
Metered Liquid Temp Range
-40°C to 90°C, Standard model
(based on 20° ambient)
-40°C to 155°C, Two piece high temperature model
-40°C to 225°C, Two piece, ultra high temperature model
Compliance
CE Certified, Ex-proof version available with ATEX/IECEx II 2 G Ex db IIB Tx Gb as well
as UL, cUL certification for Class 1, Division 1, Groups C and D, Tx
Summary of Contents for G Series
Page 24: ...G Series User Manual Rev2020A 21 Dimensions G004 SPECIFICATIONS ...
Page 26: ...G Series User Manual Rev2020A 23 Dimensions G015 SPECIFICATIONS ...
Page 28: ...G Series User Manual Rev2020A 25 Dimensions G045 SPECIFICATIONS ...
Page 30: ...G Series User Manual Rev2020A 27 Dimensions G105 SPECIFICATIONS ...
Page 35: ...G Series User Manual Rev2020A 32 Charts G105 Pressure Drop Graph G240 Pressure Drop Graph ...