G-Series User Manual Rev2020A
12
LED Functions
Normal Operation
STATUS
LED
ACTION
Functioning - System Not Flowing
Blue or Green Steady
Meter is functioning, but no flow is detected in
the system.
Functioning - System Flowing
Blue / Green alternating
colors
Meter is functioning, flow is occuring in the
system. Note: At high flow rates the alternating
Blue/Green flashes may appear as a single
steady color.
Meter Malfunction
Red Steady
Refurbish Meter.
No Power / Meter Failure
No Light
- Verify power supply to meter.
- Verify wiring follows diagrams on page 4.
- If power and wiring are verified, refurbish
meter.
Compensation via Interface Software Kit or Gold PCA Button
STATUS
LED
ACTION
Compensate button pushed/clicked
Blue Steady
- Steady light for 4-5 revolutions of meter.
Compensation Succeeded
Green Steady
- Steady light for 5 seconds.
- Software will show “Success” on screen.
Compensation Failed
Red Steady
- Steady light for 5 seconds.
- Software will show “Flow too low/ too high/
unstable” on screen.
Note: Revolutions of meter are dependent on expected fluid flow rate. Per Table A, the maximum compensation flow
rate will take approximately 10 seconds and the minimum compensation flow rate will take approximately 90 seconds
to complete 5 revolutions at the stated flow rates.
If compensation fails, restart the compensation process. When using the Interface Software Kit, follow instructions
provided to correct errors prior to attempting compensation again. If problems persist, contact Max Machinery at
707-433-2662 or at
Summary of Contents for G Series
Page 24: ...G Series User Manual Rev2020A 21 Dimensions G004 SPECIFICATIONS ...
Page 26: ...G Series User Manual Rev2020A 23 Dimensions G015 SPECIFICATIONS ...
Page 28: ...G Series User Manual Rev2020A 25 Dimensions G045 SPECIFICATIONS ...
Page 30: ...G Series User Manual Rev2020A 27 Dimensions G105 SPECIFICATIONS ...
Page 35: ...G Series User Manual Rev2020A 32 Charts G105 Pressure Drop Graph G240 Pressure Drop Graph ...