G-Series User Manual Rev2020A
10
Field Compensation of Transmitter
The transmitter LED on the circuit board indicates a functioning system when it is producing a pulse output or detecting
magnet travel in the meter.
An alternating blue/green LED indicates that the circuit is detecting a magnet and provides an output signal.
A steady or flashing red LED indicates a problem with the transmitter PCA. Contact Max Machinery to have your flow
meter refurbished.
The Compensation Algorithm adjusts for variations in Hall sensor and flow meter characteristics to provide a stable,
undamped output frequency that accurately represents the instantaneous flow rate. This feature is factory set when the
meter is assembled. If the transmitter PCA is replaced or reset, the compensation can be performed via the gold PCA
button or through the software kit.
The only method of altering additional factory set parameters of the meter is through the Interface Software Kit, part
number SFT-KIT-001. Pulse Output Scaling, Analog Output Limits and Scaling, Signal Filtering Options and Compensation
settings are the adjustable variables.
CAUTION: Before opening/accessing the electronics lid, make sure the top of
the P234 meter and surrounding components are dry and no moisture or fluids
can contact the electrical components. Non-warranty damage may occur.
!
WARNING: Electrical shock hazard. Serious or fatal injury may occur.
Access should only be completed by trained and authorized personnel.
!
Instructions to access the gold PCA button and software serial port:
- Unscrew the captured philips head screws on the electronics lid.
- Remove and set aside the lid with o-ring seal.
- Optional: follow instructions for SFT-KIT-001 to connect to software serial port.
- Follow field compensation instructions on
.
- To reinstall, ensure the o-ring seal is firmly seated. Assembly is then the reverse of disassembly.
Software Serial Port
Gold PCA Button
LED
Summary of Contents for G Series
Page 24: ...G Series User Manual Rev2020A 21 Dimensions G004 SPECIFICATIONS ...
Page 26: ...G Series User Manual Rev2020A 23 Dimensions G015 SPECIFICATIONS ...
Page 28: ...G Series User Manual Rev2020A 25 Dimensions G045 SPECIFICATIONS ...
Page 30: ...G Series User Manual Rev2020A 27 Dimensions G105 SPECIFICATIONS ...
Page 35: ...G Series User Manual Rev2020A 32 Charts G105 Pressure Drop Graph G240 Pressure Drop Graph ...