36
CHAPTeR 8: TRoUBleSHooTINg
8.10 TRoUBleSHooTINg - No ReSISTANCe ISSUeS
fIgURe A
fIgURe B
fIgURe A
fIgURe B
No ReSISTANCe TRoUBleSHooTINg
1) SyMPToM:
No resistance
2) SolUTIoN:
1) Check the power resistor wire connection between the power resistor and the LCB (Figure A).
2) Check if there is a resistance value by measuring amperage through the generator cable (Figure A).
- If there is not a resistance value, replace the resistor.
- If there is a resistance value, replace the LCB.