64
9.16 EMERGENCY STOP SWITCH REPLACEMENT
1) Turn off power and disconnect the cord from the machine.
2) Remove the console as outlined in Section 9.12.
3) Use a Phillips screwdriver to remove two screws, one from each side of the red button (Figure A).
4) Lift the button from bracket by pulling one side out at a time (Figure B).
5) Use a Phillips screwdriver to remove two screws, one from each side of the mounting bracket (Figure C).
6) Turn the bracket and use a straight screwdriver or pliers to compress each end of the switch and release it from the bracket (Figures D & E).
7) Reverse Steps 1-6 to install a new emergency stop switch.
NOTE:
Make sure the new switch has the same orientation as the old one
when installing, and that the wires are properly connected.
FIGURE A
FIGURE B
FIGURE C
FIGURE D
FIGURE E
CHAPTER 9: PART REPLACEMENT GUIDE
Summary of Contents for T7XE-03
Page 1: ...T 7 X E 0 3 T R E A D M I L L S E R V I C E M A N U A L...
Page 4: ...1 1 1 SERIAL NUMBER LOCATION CHAPTER 1 SERIAL NUMBER LOCATION...
Page 29: ...26 8 1 ELECTRICAL DIAGRAMS CHAPTER 8 TROUBLESHOOTING...
Page 30: ...27 8 1 ELECTRICAL DIAGRAMS P29 DIGITAL COMMUNICATION WIRE CHAPTER 8 TROUBLESHOOTING...
Page 31: ...28 8 1 ELECTRICAL DIAGRAMS N95 UCB LITTLE BOARD WIRE CHAPTER 8 TROUBLESHOOTING...
Page 32: ...29 N97 HAND PULSE WIRE CHAPTER 8 TROUBLESHOOTING 8 1 ELECTRICAL DIAGRAMS...
Page 84: ...81 NOTES...