57
CHAPTER 9: PART REPLACEMENT GUIDE
9.11 INCLINE MOTOR REPLACEMENT - CONTINUED
FIGURE D
FIGURE E
FIGURE F
FIGURE G
5) Disconnect the incline motor power cable from the MCB (Figure D).
6) Disconnect the pin from the top of the incline motor (Figure E).
7) Lift the incline motor away from the treadmill (Figure F).
8) Reverse Steps 1-7 to install a new incline motor. When installing the new motor, the worm screw should be turned as short as possible, and
then rotated out 2 full turns prior to being re-attached to the rack.
NOTE:
When installing the new incline motor, make sure to replace the white
washers at the top and bottom connection points of the incline motor (Figure G).
9) Auto Calibration must ALWAYS be run after replacing the incline motor (see Section 3.5).