36
7.6 Error message
0140 / 01
A
0 / 01
A
2
troubleshooting
[Symptom ]
0140 - Incline motor operation failed.
01A0 - Incline motor disconnected.
01A2 - Incline motor is detected in the reverse of the position indicated by the potentiometer.
[Solution]
a. Check the connection of the incline motor cable at the MCB.
b. Run auto calibration.
c. If auto calibration fails, re-enter Engineering Mode and go to Calibration again.
- Select Incline Minimum, and then Go To Value.
- Check the MCB LEDs. If LED2 DOWN (Figure B) has no light, check the console cable
connections at the console and MCB. Replace the console or cable as needed. If LED2 DOWN
has a light, replace the incline motor.
d. If the issue is not solved by replacing the incline motor, replace the MCB.
Figure A
Summary of Contents for T50x-02
Page 1: ...1 Matrix T50x 02 T50x U 02 SERVICE MANUAL...
Page 5: ...5 SECTION 1 SERIAL NUMBER LOCATION...
Page 6: ...6 Matrix T50x Serial Number Location...
Page 7: ...7 SECTION 2 MOVING THE UNIT...
Page 9: ...9 SECTION 3 IMPORTANT SAFETY INSTRUCTIONS...
Page 13: ...13 SECTION 4 PREVENTATIVE MAINTENANCE...
Page 22: ...22 SECTION 5 OVERLAY AND WORKOUT DESCRIPTION...
Page 25: ...25 SECTION 6 ENGINEERING MODE...
Page 29: ...29 SECTION 7 TROUBLE SHOOTINGS...
Page 30: ...30 7 1 Electrical block diagram...
Page 31: ...31 7 2 Wire pin definition W35 Digital Comm Wire W38 Grip Pulse Wire...
Page 32: ...32 7 3 MCB LED instruction...
Page 50: ...50 SECTION 8 PARTS REPLACEMENT...
Page 62: ...62 Figure D Figure E Figure F Figure G...
Page 68: ...68 Install the MSP430 Tools Computer...
Page 69: ...69 Press the Load Image Installation software to MSP430 Tools...
Page 70: ...70 Installing the MSP430 cable to console MSP430...