46
7.16 Error message
02A2 / 0241
troubleshooting
Figure A
[Symptom ]
02A2 - DC high voltage converter to detect the internal side of over-voltage phenomenon.
0241 - DC high voltage side of the internal drive is too low to detect.
[Solution]
a. Please check if the input power is normal and reboot power again.(Figure A)
b. Replace the MCB.
Summary of Contents for T50x-02
Page 1: ...1 Matrix T50x 02 T50x U 02 SERVICE MANUAL...
Page 5: ...5 SECTION 1 SERIAL NUMBER LOCATION...
Page 6: ...6 Matrix T50x Serial Number Location...
Page 7: ...7 SECTION 2 MOVING THE UNIT...
Page 9: ...9 SECTION 3 IMPORTANT SAFETY INSTRUCTIONS...
Page 13: ...13 SECTION 4 PREVENTATIVE MAINTENANCE...
Page 22: ...22 SECTION 5 OVERLAY AND WORKOUT DESCRIPTION...
Page 25: ...25 SECTION 6 ENGINEERING MODE...
Page 29: ...29 SECTION 7 TROUBLE SHOOTINGS...
Page 30: ...30 7 1 Electrical block diagram...
Page 31: ...31 7 2 Wire pin definition W35 Digital Comm Wire W38 Grip Pulse Wire...
Page 32: ...32 7 3 MCB LED instruction...
Page 50: ...50 SECTION 8 PARTS REPLACEMENT...
Page 62: ...62 Figure D Figure E Figure F Figure G...
Page 68: ...68 Install the MSP430 Tools Computer...
Page 69: ...69 Press the Load Image Installation software to MSP430 Tools...
Page 70: ...70 Installing the MSP430 cable to console MSP430...