Long press the current adjustment knob to enter the OCP function setting (as shown in the figure below), at
this time, if you want to change the OCP setting value, you can lightly press the current adjustment knob. The
current window number corresponding to the current adjustment knob will flash. Turn the knob left and right
To change the setting value, lightly press the knob in the setting state to change the setting position. If you
want to open or close the OCP function, you can lightly press the voltage adjustment knob and then turn the
knob left and right to change the fixed value ON/OFF (ON is to open the OCP function, OFF is to close the
OCP function)
2. OVP setting:
Long press the voltage adjustment knob to enter the OVP function setting (as shown in the figure below), at
this time, if you want to change the OVP setting value, you can tap the voltage adjustment knob and the
corresponding voltage window number will flash. Turn the knob left and right to change the setting Value, in
the setting state, lightly press the knob to change the setting position. If you want to turn on or off the OVP
function, you can lightly press the current adjustment knob and then turn the knob left and right to change
the fixed value ON/OFF (ON is to open the OVP function, and OFF is to close the OVP function).
3. OCP protection:
When the output current exceeds the OCP setting value, the current window will prompt "OCP" and turn off
the output (as shown below).