![Matrix MPS-H-1 Series User Manual Download Page 13](http://html.mh-extra.com/html/matrix/mps-h-1-series/mps-h-1-series_user-manual_1740899013.webp)
www.szmatrix.com
8
4. Remote compensation function: SENSE ON/OFF (ON means remote compensation is turned on, OFF means
remote compensation is turned off, the current knob is used to switch the menu steps, the voltage knob is
used to switch the ON/OFF state, and lightly press the "output switch/menu function button" "Exit the menu.)
5. Voltage lower limit setting: VOL-L 0.000 (The voltage display window is the lower voltage limit. Use the
current knob to switch the menu steps. Press the voltage knob and the voltage window value flashes. At this
time, you can turn the knob left and right to change the lower voltage limit. Tap the knob to change the
setting position, tap the "output switch/menu function button" to exit the menu.)
6.Voltage upper limit setting: VOL-H 31.000 (The voltage display window is the voltage upper limit. Use the
current knob to switch the menu steps. Press the voltage knob and the voltage window value flashes. At this
time, you can turn the knob left and right to change the voltage upper limit, and press Turn the knob to