MSC-CP32X1E Product Manual
Lock
Get video lock status and rate detection
information (not all HD router systems are
supported).
MAC
Query system MAC address
MascotVer
Query Mascot protocol version.
MtxCfg * (2.0)
[0-7]
Query current matrix config.
Mt (2.4)
[LVL1][LVL2]
Query or assign I/O grouping.
NetMask
[NETMASK]
Query or assign network mask.
(2.1)
[0 | 1]
Query or assign I/O pairing enable (3D
support).
MtxGroup supersedes this
command.
PanelDis (2.4)
[0 | 1]
Query or assign internal panel button
interface disable.
PanelExtEn (2.4)
[0 | 1]
Query or assign external panel interface
enable (if available).
PanelOfs (2.1)
[DEST][SRC]
[LVL1][LVL2]
Query or assign button panel
destination/source offsets and levels to
control. Useful for configuring multiple
panels to control different I/O regions of a
router.
PanelRate (2.1)
[RATE]
Set remote panel refresh rate in seconds.
PsetNames *
[PRESET][LABEL] Query or assign preset names.
Reboot
Reboot the system.
Re (2.1)
[0 | 1]
Disable SDI reclockers (not all SDI router
systems are supported).
Remo (2.1)
[0 | 1]
Query or assign remote router syncing.
Useful for creating a 3D system out of 2
routers.
(2.4)
[0 | 1]
Query or assign Sierra Video Systems
protocol enable on serial port interface.
SrcNames *
[SRC][LEVEL]
[LABEL]
Query or assign source names.
SysName
[STR]
Query or assign system name.
WebPass
(STR)
Assign web password.
* Router systems and MSC-GCP2U32 LCD panel only.
+ Router systems only.
3.9 B Command
The B command is used for rebooting the system into Bootloader for software updates. See the Software
Update section for details.
3.10 C Command
Routers and MSC-GCP2U32 only
NOTE:
Page 20 of 48
Copyright © 2013-2015 Matrix Switch Corporation