background image

 

Command Summary

 

37 

 

10.3

 

Poll Key 

Press 

Dec 
Hex 
ASCII

 

254 38 

FE 26 

 & 

 

v8.0 

Reads the last unread key press from the 10 key display buffer.  If another key is stored in the buffer the MSb will 
be 1, the MSb will be 0 when the last key press is read.  If there are no stored key presses a value of 0 will be 
returned.  Auto transmit key presses must be turned off for this command to be successful, do not use with I

2

C. 

Response 

Byte  

Value of key pressed (MSb determines additional keys to be read). 

 

 

10.4

 

Clear 

Key Buffer 

Dec 
Hex 
ASCII

 

254 69 

FE 45 

 E 

 

v8.0 

Clears all key presses from the key buffer. 

 

 

10.5

 

Set 

Debounce Time 

Dec 
Hex 
ASCII

 

254 85 

FE 55 

 U 

Time 
Time 
Time 

v8.0 

Sets the time between a key press and a key read by the display.  Most switches will bounce when pressed; the 
debounce time allows the switch to settle for an accurate read.  Default is 8 representing approximately 52ms. 

Time 

Byte  

Debounce increment (debounce time = 

Time

 * 6.554ms). 

 
 

10.6

 

Set Auto 

Repeat Mode 

Dec 
Hex 
ASCII 

254 126 

FE 7E 

 

DEL

 

Mode 
Mode 
Mode 

v8.0 

Sets key press repeat mode to typematic or hold.  In typematic mode if a key press is held, by default the key value 
is transmitted immediately, then 5 times a second after a 1 second delay.  In hold mode, the key down value is 
transmitted once when pressed, and then the key up value is sent when the key is released.  Default is typematic. 

Mode 

Byte  

1 for hold mode or 0 for typematic. 

 

 

10.7

 

Auto 

Repeat Mode Off 

Dec 
Hex 
ASCII 

254 96 

FE 60 

 ` 

 

v8.0 

Turns auto repeat mode off.  Default is on (typematic). 

 

 

 

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for GLK24064-25

Page 1: ...24064 25 GLT24064 Including GLK24064 25 USB GLK24064 25 422 GLT24064 USB and GLT24064 422 Technical Manual Revision 3 2 PCB Revision 4 0 or Higher Firmware Revision 8 1 or Higher Downloaded from Arrow com ...

Page 2: ...ng Options Martino 2 7 September 9 2013 Corrected Scripted Button Key and Keypad Brightness Commands Clark 2 6 July 10 2013 Updated Data Packet Size Definitions Clark 2 5 December 13 2012 Added Firmware Revision 8 4 Commands Clark 2 4 October 23 2012 Added Alternate Power requirement for YG units Clark 2 3 October 13 2011 Major Command Additions Clark 2 2 March 8 2011 Updated Electrical Specificat...

Page 3: ... 7 3 1 MOGD 7 3 2 Firmware Upgrade 8 3 3 Application Notes 8 4 Hardware 9 4 1 Standard Model 9 Extended Communication Power Header 9 Serial DB9 Connector 9 Power Through DB9 Jumper 10 Protocol Select Jumpers 10 Hardware Lock 10 4 2 USB Model 11 Mini USB Connector 11 Alternate USB Header 11 Alternate Power Connector 11 4 3 RS422 Model 12 RS422 Header 12 Alternate Power Connector 12 Downloaded from ...

Page 4: ...al Override 17 6 Commands 18 6 1 Communication 18 Text 20 6 2 Drawing 22 6 3 Fonts 27 Font File Creation 28 6 4 Bitmaps 30 Bitmap File Creation 31 Bitmap Masking 31 6 5 9 Slices 32 9 Slice File Creation 32 6 6 Animations 33 Animation File Creation 34 6 7 General Purpose Output 34 6 8 Dallas One Wire 35 6 9 Piezo Buzzer 36 6 10 Keypad 36 6 11 Touchpad 38 Downloaded from Arrow com Downloaded from Ar...

Page 5: ...mary 52 7 2 Block Diagram 57 7 3 Environmental Specifications 57 7 4 Electrical Tolerances 57 7 5 Dimensional Drawings 58 7 1 Optical Characteristics 60 8 Ordering 60 8 1 Part Numbering Scheme 60 8 2 Options 60 8 3 Accessories 61 9 Definitions 63 10 Contact 63 Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com ...

Page 6: ...g backlight brightness screen contrast and baud rate On board memory provides a whopping 256KB of customizable fonts and bitmaps to enhance the graphical user experience User input on the GLK24064 25 is available through a five by five matrix style keypad or a resistive touch overlay on the GLT24064 Six general purpose outputs provide simple switchable five volt sources on each model In addition a...

Page 7: ...ector ESCCPC5V BBC Standard Model Only 3 Alternate Power Connector PCS 422 and USB Models Only 4 Mini USB Connector EXTMUSB3FT INTMUSB3FT USB Model Only 5 GPO Header None Offered All Models 6 DB9 Serial Header CSS1FT CSS4FT Standard Model Only 7 Keypad KPP4x4 GLK Model Only Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow...

Page 8: ...board Cable BBC For a more flexible interface to the GLK24064 25 GLT24064 a Breadboard Cable may be used This provides a simple four wire connection that is popular among developers for its ease of use in a breadboard environment Serial Connections Serial protocol provides a classic connection to the GLK24064 25 GLT24064 The Extended Communication Power Cable is most commonly used for this set up ...

Page 9: ...GLK24064 25 GLT24064 in I2 C mode get started with the guidelines below 1 Set the Protocol Select switches I2 C Ensure that the two I2 C jumpers in the corresponding protocol box are connected while all others are open 2 Make the connections a Connect the Breadboard Cable to the Communication Power Header on your GLK24064 25 GLT24064 and plug the four leads into your breadboard The red lead will r...

Page 10: ...o operate in USB Protocol Select jumpers on the USB model cannot be moved 2 Make the connections Plug the mini B header of your External Mini USB cable into your GLK24064 25 USB GLT24064 USB and the regular USB header into your computer USB jack 3 Install the drivers a Download the latest drivers at www matrixorbital ca drivers and save them to a known location b When prompted install the USB bus ...

Page 11: ...umper changes 2 Make the connections a Screw one wire sized 16 to 30 on the American Wire Gauge into each of the six terminal block positions When local power is supplied a floppy cable may link to the alternate power header b Connect the Vcc wire to the positive terminal of your power supply and the GND terminal to the negative or ground lead to provide appropriate power as per Voltage Specificat...

Page 12: ...a free download from www matrixorbital ca software software_graphic It provides a simple graphical interface that allows settings fonts and bitmaps to be easily customised for any application While monochromatic bitmaps can easily be created in virtually any image editing program MOGD provides an extensive font generation suite to stylize your display to any project design In addition to standard ...

Page 13: ... ordered as a part of a custom order Please use the Contact section to request more information from the Matrix Orbital sales team 3 3 Application Notes Full demonstration programs and code are available for Matrix Orbital displays in the C language from Simple C AppNote Pack in the Application Note section at www matrixorbital ca appnotes Difficulty increases from beginner with the Hello World pr...

Page 14: ... mated to a number of connectors a 22 01 1062 for example Serial DB9 Connector Figure 8 Serial DB9 Connector Table 5 Serial DB9 Pinout Pin Function 2 Tx 3 Rx 5 Gnd 7 CTS 8 RTS 9 NC Vcc The GLK24064 25 GLT24064 provides a DB 9 Connector to readily interface with serial devices using EIA232 standard signal levels It is also possible to communicate at TTL levels of 0 to 5V by setting the Protocol Sel...

Page 15: ...jumpers The display will now be in I C mode and have a default slave address of 80 unless changed with the appropriate command Similarly in order to change the display to TTL mode simply remove the zero ohm resistors from the RS232 or I C jumpers and solder them to the TTL jumpers Hardware Lock The Hardware Lock allows fonts bitmaps and settings to be saved unaltered by any commands By connecting ...

Page 16: ...request more information from the friendly Matrix Orbital sales team Alternate Power Connector Figure 11 Alternate Power Connector Table 7 Alternate Power Pinout Pin Function 1 Vcc 2 Gnd 3 Gnd 4 NC The Alternate Power Connector provides the ability to power the GLK24064 25 USB GLT24064 USB using a second cable The Tyco 171825 4 style header is particularly useful for connecting to an unmodified fl...

Page 17: ...r Connector Table 9 Alternate Power Pinout Pin Function 1 Vcc 2 Gnd 3 Gnd 4 NC The Alternate Power Connector provides the ability to power the GLK24064 25 USB GLT24064 USB using a second cable The Tyco 171825 4 style header is particularly useful for connecting to an unmodified floppy power cable a 171822 4 for example from a PC power supply for a simple bench power solution Downloaded from Arrow ...

Page 18: ...ed using the Assign Key Codes command The straight twelve pin header of the Keypad Interface Connector will interface to a variety of different devices including the Matrix Orbital KPP4x4 keypad Note In I 2 C mode the Auto Transmit Keypress function should always be on keypresses should not be polled Note The Ground 5V pin is toggled by the jumpers to the right of the keypad connector Placing a 0 ...

Page 19: ...pler keypad style alternative to coordinate mode region mode offers only a single byte for each touch event Unique regions are created by specifying a position size and return values A value corresponding to a specific region is returned when an event occurs within its bounds Events outside of regions result in transmission of the value 255 Regions can be deleted individually or collectively when ...

Page 20: ...igure 16 Dallas One Wire Connector Table 14 Dallas One Wire Pinout Pin Function 1 Vcc 2 D 3 Gnd In addition to the six general purpose outputs the GLK24064 25 GLT24064 offers an Optional Dallas One Wire bridge to allow for an additional thirty two one wire devices to be connected to the display This header can be populated with a Tyco 173979 connector at an added cost by custom order only Please u...

Page 21: ...l for more information 5 2 Display If your display is powered successfully the Matrix Orbital logo or user created screen should display on start up If this is not the case check out these tips Ensure the contrast is not too high or too low This can result in a darkened or blank screen respectively See the Manual Override section to reset to default Make sure that the start screen is not blank It ...

Page 22: ...usability the default settings can be temporarily restored To override the display please follow the steps below 1 Disconnect power from your display 2 Place a jumper on the two manual override pins for the GLK24064 25 model these are the middle two keypad pins for the GLT24064 these are the two pins near the keypad header 3 Reconnect power to your unit and wait for the start screen before removin...

Page 23: ...he value specified Baud must be a whole number between 0 and 1 000 000 Not available in I2C Can be temporarily forced to 19200 by a manual override Baud Integer Baud rate speed The value must be sent using little endian format Note Command was restructured at firmware revision 8 0 1 5 Set Flow Control Mode Dec Hex ASCII 254 63 FE 3F Mode Mode Mode v8 0 Toggles flow control between hardware softwar...

Page 24: ...x ASCII 254 60 FE 3C Xon Xoff Xon Xoff Xon Xoff v8 0 Sets the values returned for almost full and almost empty messages when in flow control mode This command permits the display to utilize standard flow control values of 0x11 and 0x13 note that defaults are 0xFF and 0xFE Xon Byte Value returned when display buffer is almost empty permitting transmission to resume Xoff Byte Value returned when dis...

Page 25: ... character is printed X Byte Value between 1 and screen width represents leftmost character position Y Byte Value between 1 and screen height represents topmost character position 1 17 Get String Extents Dec Hex ASCII 254 41 FE 29 Text Text Text v8 6 Read the size of the rectangle that the specified string would occupy if it was rendered with the current font Text String String on which to preform...

Page 26: ... X1 Y1 X2 Y2 Vert Hor Font Background CharSpace ID X1 Y1 X2 Y2 Vert Hor Font Background CharSpace v8 3 Designates a portion of the screen that can be easily updated with one line of text often used to display variables ID Byte Unique label identification number value between 0 and 15 X1 Byte Leftmost coordinate Y1 Byte Topmost coordinate X2 Byte Rightmost coordinate Y2 Byte Bottommost coordinate V...

Page 27: ...ique label to update between 0 and 15 Data String Information to display in the label must be terminated with a null value of zero byte 1 24 Auto Scroll On Dec Hex ASCII 254 81 FE 51 Q v8 0 The entire contents of screen are shifted up one line when the end of the screen is reached Display default is on 1 25 Auto Scroll Off Dec Hex ASCII 254 82 FE 52 R v8 0 New text is written over the top line whe...

Page 28: ...ored Colour Byte 0 for background or any other value for text colour X1 Byte Leftmost coordinate Y1 Byte Topmost coordinate X2 Byte Rightmost coordinate Y2 Byte Bottommost coordinate 2 6 Draw a Filled Rectangle Dec Hex ASCII 254 120 FE 78 x Colour X1 Y1 X2 Y2 Colour X1 Y1 X2 Y2 Colour X1 Y1 X2 Y2 v8 0 Draw a filled rectangle using the colour specified current drawing colour is ignored Colour Byte ...

Page 29: ...e current drawing colour X Byte Horizontal coordinate of the circle centre Y Byte Vertical coordinate of the circle centre Radius Byte Distance between the circle perimeter and centre 2 11 Draw an Ellipse Dec Hex ASCII 254 125 FE 7D X Y XRadius YRadius X Y XRadius YRadius X Y XRadius YRadius v8 3 Draw an elliptical frame one pixel wide using the current drawing colour X Byte Horizontal coordinate ...

Page 30: ... ID Type X1 Y1 X2 Y2 ID Type X1 Y1 X2 Y2 ID Type X1 Y1 X2 Y2 v8 3 Initialize a bar graph in memory for later implementation Graphs can be located anywhere on the screen but overlapping may cause distortion Graph should be filled using the Draw a Bar Graph command ID Byte Unique bar identification number between 0 and 255 Type Byte Graph style see Bar Graph Types X1 Byte Leftmost coordinate Y1 Byte...

Page 31: ...D Value ID Value v8 3 Fill in a portion of a bar graph after initialization Any old value will be overwritten by the new Setting a value of zero before setting a new value will restore a graph should it become corrupted ID Byte Unique bar identification number between 0 and 255 Value Byte Portion of graph to fill in pixels will not exceed display bounds Downloaded from Arrow com Downloaded from Ar...

Page 32: ...arated Box 2 18 Update a Strip Chart Dec Hex ASCII 254 111 FE 6F o ID Value ID Value ID Value v8 3 Shift the specified strip chart and draw a new value ID Byte Chart identification number value between 0 and 7 Value Short Value to add to the chart 6 3 Fonts 3 1 Upload a Font File Dec Hex ASCII 254 36 FE 24 ID Size Data ID Size Data ID Size Data v8 0 Upload a font to a graphic display To create a f...

Page 33: ...atrix Orbital graphic display is loaded with a small filled font in slot one and a future bk bt 16 style in slot two Both are available at www matrixorbital ca software graphic_fonts The easiest way to create add or modify the fonts of any graphic display is through the MOGD tool This provides a simple graphic interface that hides the more complex intricacies of the font file Table 22 Example Font...

Page 34: ... by writing a one in their location and cleared by setting a value of zero Starting at the top left moving right then down eight of these cells form a character data byte When all cells are accounted for zeroes may be added to the last byte to complete it A sample of an h glyph is shown above The data for the i and j characters will follow to complete the custom font file displayed below Table 26 ...

Page 35: ... coordinate of bitmap Note ID and Size were changed from Byte and Short lengths respectively at firmware revision 8 1 4 4 Draw a Partial Bitmap Dec Hex ASCII 254 192 FE C0 ID X Y XPart YPart Width Height ID X Y XPart YPart Width Height ID X Y XPart YPart Width Height v8 6 Draw a portion of a previously uploaded bitmap confined to the width and height specified ID Short Unique bitmap identification...

Page 36: ...0 1 0 0 0 0 0 0 1 0 0 0 1 0 1 1 1 0 Table 28 Smiley Face Data 0 1 0 1 0 0 0 0 50 80 0 0 1 0 0 0 1 0 22 34 1 1 1 0 0 0 0 0 E0 224 Table 29 Example Bitmap File Header 5 4 Bitmap Data 80 34 224 Bitmap Masking Like a regular bitmap a mask can be loaded to the display and used to create a more polished result when drawing in populated areas When defining a mask all active values will clear any backgrou...

Page 37: ... value between 0 and 1023 X1 Byte Leftmost coordinate of the 9 slice Y1 Byte Topmost coordinate of the 9 slice X2 Byte Rightmost coordinate of the 9 slice Y2 Byte Bottommost coordinate of the 9 slice 9 Slice File Creation A 9 slice file is a scalable graphic composed of nine different bitmap sections as shown below Figure 19 Adobe 9 slice Representation The 9 slice file format requires that the bi...

Page 38: ...to play the displayed file ID Byte Unique animation identification number value between 0 and 15 File ID Short Unique animation file identification number value between 0 and 1023 X Byte Leftmost coordinate of animation Y Byte Topmost coordinate of animation Note File ID word length variable was removed from this command at v8 4 and reintroduced in v8 5 6 3 Delete Animation Dec Hex ASCII 254 199 F...

Page 39: ... bitmap data as per the Bitmap File Creation example Header 9 Two bytes one representing the width and one the height of the last bitmap Bitmap 9 Data The last bitmap data as per the Bitmap File Creation example 6 7 General Purpose Output 7 1 General Purpose Output On Dec Hex ASCII 254 87 FE 57 W Number Number Number v8 0 Turns the specified GPO on sourcing current from an output of five volts Num...

Page 40: ...Number of bytes to be sent to the device Receive Bits Byte Number of bytes expected to be received from the device Data Byte s Data to be transmitted LSB to MSB Table 33 Dallas One Wire Flags Bit Flag Description 7 6 Unused 5 4 0 Future Compatibility 3 Add CRC8 to transaction 2 0 Future Compatibility 1 Read CRC8 from transaction 0 Reset Bus prior to transaction Table 34 Dallas One Wire Errors Code...

Page 41: ... down event beep in Hertz default is 0 or off Up Freq Short Frequency of the up event beep in Hertz default is 0 or off 6 10 Keypad 10 1 Auto Transmit Key Presses On Dec Hex ASCII 254 65 FE 41 A v8 0 Key presses are automatically sent to the host when received by the display Use this mode for I2C transactions 10 2 Auto Transmit Key Presses Off Dec Hex ASCII 254 79 FE 4F O v8 0 Key presses are held...

Page 42: ... In hold mode the key down value is transmitted once when pressed and then the key up value is sent when the key is released Default is typematic Mode Byte 1 for hold mode or 0 for typematic 10 7 Auto Repeat Mode Off Dec Hex ASCII 254 96 FE 60 v8 0 Turns auto repeat mode off Default is on typematic Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow ...

Page 43: ... 200ms 6 11 Touchpad 11 1 Set Touch Mode Dec Hex ASCII 254 135 FE 87 ç Mode Mode Mode v8 0 Sets the method used to return touch events Region mode will return a single value for events in defined areas Coordinate mode will return event x position and y position bytes for each press drag or release Mode Byte Touch reporting mode 0 for region or 1 for coordinate mode Default is coordinate Downloaded...

Page 44: ...ouch region Events from undefined regions return the value 255 by default ID Byte Unique region identification number 11 5 Delete All Touch Regions Dec Hex ASCII 254 134 FE 86 å v8 0 Deletes all previously created touch regions Recommended for use before dividing the screen into new regions Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Down...

Page 45: ...BE v8 3 Deletes all previously created sliders Does not remove touch regions 11 9 Set Dragging Threshold Dec Hex ASCII 254 137 FE 89 ë Threshold Threshold Threshold v8 0 Sets the distance a press is required to travel before a drag event is reported Precision will vary inversely to data transmitted care should be taken to find a suitable balance Distance is calculated as 𝑥2 y2 𝑑2 Threshold Byte Dr...

Page 46: ...tness level from 0 Dim to 255 Bright 12 4 Set and Save Brightness Dec Hex ASCII 254 152 FE 98 ÿ Brightness Brightness Brightness v8 0 Immediately sets and saves the backlight brightness Although brightness can be changed using the set command it is reset to this saved value on start up Default is 255 Brightness Byte Brightness level from 0 Dim to 255 Bright Downloaded from Arrow com Downloaded fro...

Page 47: ...able Row Byte The row value of the key to be linked to the specified scripts Column Byte The column value of the key to be linked to the specified scripts Down Script Short Identification number of the script to run on a down event value between 0 and 1023 Up Script Short Identification number of the script to run on an up event value between 0 and 1023 Note The command number for Set Scripted Key...

Page 48: ... after deletion Type Byte 0 for font or 1 for bitmap ID Short Unique identification number of font or bitmap to be deleted value between 0 and 1023 Note ID was changed from a Byte length at firmware revision 8 1 14 3 Get Filesystem Space Dec Hex ASCII 254 175 FE AF v8 0 Returns the amount of space remaining in the display for font or bitmap uploads Response Integer Number of bytes remaining in mem...

Page 49: ...E B2 Type ID Type ID Type ID v8 0 Downloads a single font or bitmap file from the display to the host using the File Transfer Protocol Type Byte Variable length see File Types ID Short Unique identification number of font or bitmap to download value between 0 and 1023 Response Integer File size Byte s File data Note ID was changed from a Byte length at firmware revision 8 1 Downloaded from Arrow c...

Page 50: ...Size Data File ID Type Size Data v8 3 This command will upload a single file to the display Unlike the standard protocol there is one XModem upload command for all file types see File Types for a complete list File ID Word Unique identification number for the file to upload Type Byte Type of file to upload see File Types Size Double Size of the file to upload Data Byte s File data to upload must b...

Page 51: ...value originally sent before a confirmation byte of 1 is returned If the transmitted and echoed values do not match the upload should be aborted by sending a value of 8 instead The upload will continue in this manner as indicated by the examples below which utilize familiar font and bitmap files Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com...

Page 52: ...the regular protocol If the file will fit the start of header byte will be sent by the host followed by a block count in regular and inverted format representing the number of 128 byte blocks remaining to be sent The display will then check to make sure the block count value matches its own if it doesn t it will NAK The host can then send a 128 byte block of data followed by that blocks high and l...

Page 53: ...ng the XMODEM CRC CCITT algorithm available at http www matrixorbital ca appnotes XModem ymodem txt Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded fro...

Page 54: ...is 0 Level Byte See Data Lock Bits table 6 16 Miscellaneous 16 1 Write Customer Data Dec Hex ASCII 254 52 FE 34 4 Data Data Data v8 0 Saves a user defined block of data to non volatile memory Useful for storing display information for later use Data Byte 16 User defined data Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arro...

Page 55: ...e Module Type Responses for a partial list Table 50 Sample Module Type Responses 105 GLT24064 21 GLK24064 25 106 GLT24064 USB 107 GLK24064 25 USB 110 GLT24064 422 109 GLK24064 25 422 Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloade...

Page 56: ...Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com ...

Page 57: ...2 Short Byte None Remember On Update Label 46 2E Byte String None Never Auto Scroll On 81 51 Q None None Remember On Auto Scroll Off 82 52 R None None Remember On Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Dow...

Page 58: ... Byte See Bitmap File Creation Always Draw a Bitmap from Memory 98 62 b Short Byte 2 None Never Draw a Partial Bitmap 192 C0 Short Byte 6 None Never Draw a Bitmap Directly 100 64 d Byte 2 Byte None Never Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded fro...

Page 59: ...82 B6 Short 2 None Remember On Set Touch Buzzer Beep 182 B6 Short 2 None Remember On Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Dow...

Page 60: ...Parameters Response Remembered Upload a Script File 92 2 5C 02 STX Short Integer Byte None Always Set Scripted Key 142 8E Ä Byte 3 Short 2 Byte Short 2 None Remember On Set Scripted Button 141 8D ì Byte 3 Short 2 None Remember On Run Script File 93 5D Short None Never Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com D...

Page 61: ...55 37 7 None Byte Never Read Screen 184 B8 None Byte Byte Byte Never Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arr...

Page 62: ... Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloade...

Page 63: ...loaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded fro...

Page 64: ...loaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded fro...

Page 65: ...d from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arr...

Page 66: ... com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downl...

Page 67: ...m Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Download...

Page 68: ...ial protocol Low level is 0V while high logic is 5V 10 Contact Sales Phone 403 229 2737 Email sales matrixorbital ca Support Phone 403 204 3750 Email support matrixorbital ca Online Purchasing www matrixorbital com Support www matrixorbital ca Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com ...

Reviews: