Operating manual
DF 500
MATO
GmbH & Co. KG
/ Benzstr. 16-24 / 63165 Mühlheim a. Main / Tel:+49(0)6108-906-0 / Fax:+49(0)6108-906-120
6 Trouble Shooting:
Symptom
possible Cause
repairing
No grease delivery.
Grease container is empty.
Grease intake is interrupted.
No air pressure at the pump.
Check grease level in the container.
Vent the pump.
Check the air supply.
7 Tecnical Specifications:
pneuMATO
DF 500
Pressure ratio
Max. working pressure of 8 bar air inlet pressure
Air inlet pressure min./max.
Delivery rate (per stroke):
Loudness:
1:60
480 bar
3 – 8 bar
1 ccm/Stroke
ca. 85
dB(A)
Temperature of grease
(lower temperatures are possible, depending on
the fluidity of grease)
5°C bis +50°C
Threads
Air inlet
Grease outlet
R 1/4“ f
R 1/8“ f
Weight
1,8 kg
Lubricants:
Greases up to consistency 2 (NLGI / Class 2 to DIN 51818) can be used. Pastes with no lubrication
properties (with abrasive emery contents) must not be used with this equipment.
8 Disposal
The device must be disposed of according to the valid legal regulations
at the end of its service life.
Grease contaminated parts do not belong in the garbage.
Your contribution to environmental protection:
The operator must strictly adhere to the valid regulations regarding display, installation and
operating of plants for handling water-endangering materials. (such as, for example WHG, VawS
and TRbF)
10