Operating instructions
200 l - 1000l IBC
MATO
GmbH & Co. KG
/ Benzstr. 16-24 / 63165 Mühlheim a. Main / Tel:00 49(0)6108-906-0 / Fax: 00 49(0)6108-906-120
6
Notes in case of malfunctions:
Symptoms
Possible causes
Removal
The engine does not run.
Power plug not in socket
Terminal posts not connected
Battery is weak or empty
Wiring to the motor defective.
Plug the mains plug into the socket
Connect terminal posts correctly
Check battery voltage.
Repair by qualified electrician
Pump does not convey
The container is empty
Suction line is leaking.
Suction filter is clogged
Check fill level in the tank.
Check suction line for leaks.
Clean suction filter
Pump stops continuously
with the delivery.
Suction filter is clogged
Clean suction filter
7
Specifications:
Type
SB 23
–
12V
SB 23
–
230V
SB 30
–
230V
SB 32
–
12V
SB 32
–
24V
Tension
12V DC
230V AC
230V AC
12 / 24V DC
Frequency
-
50/60Hz
50/60Hz
-
Power supply
10A
1.5A
1.5A
12A / 6A
Protection type
IP54
IP54
IP54
IP54
Engine power
0.12kW
0.18kW
0.37kW
0.18kW
Max. flow rate
(free outlet)
23 l/min
23 l/min
30 l/min
32 l/min
Max. delivery pressure
1,6bar
1,6bar
1,6bar
1,6bar
Suction height
3m
3m
3m
3m
Thread
1“ BSP
1“ BSP
1“ BSP
1“ BSP
Volume
approx. 70
dB(A)
approx. 70
dB(A)
approx. 70
dB(A)
approx. 70
dB(A)
Temperature range
-5°C to 40°C
-5°C to 40°C
-5°C to 40°C
-5°C to 40°C
Dimensions
L x B x H (mm)
290
x
160
x
110
260
x
160
x
140
275
x
180
x
175
275
x
180
x
175
Dimensions l x b (mm)
58x80
80x100
80x100
80x100
Weight
(Pump without accessories)
3.5kg
4.4kg
5.6kg
5.0kg
13