SETTING THE  CONTROLS

1. 

Put the LUX control knob to light (

) position, turn the wall switch on and wait half a minute for  

 

the control circuit to stabilize. At this stage ensure that the TIME control knob is set at minimum  

 

duration time (-) position. The connected circuit will now switch on and remain on for about 30  

 

seconds (within 60 seconds).

2. 

Have another person move across the desired perimeter of the area to be scanned and slowly  

 

adjust the SENS knob until the unit activates. Note reducing SENS will reduce both normal and  

 

occupancy zones

3. 

To set the light level at which the lights will automatically switch “on” at night, turn the LUX con 

 

trol knob from daylight (

) to night (

). If the lights are required to switch on earlier, e. g. Dusk,  

 

wait for the desired light level, and then slowly turn the LUX control knob towards daylight while  

 

someone walks across the center of the area to be detected. When the lights activate, release  

 

the LUX control knob. You may need further slight adjustments to achieve your ideal light level  

 setting

4. 

Once LUX and SENS are calibrated, adjust TIME to suit site requirements.

5. 

Duplicate these settings for similar locations