Matelec FMS-12080 Instructions Download Page 3

MATELEC AUSTRALIA.  P 1800 281 282.  F 1300 281 282

[email protected].    WWW.MATELECAUSTRALIA.COM.AU

SET  UP AND ADJUSTMENT

LIGHT CONTROL SETTING:

The Lux control is a built-in sensing device (photocell) that detects daylight and darkness.(

) position 

denotes the light can activate during daylight and night. (

) position denotes the light can activate 

only at night. You can set the unit to operate at the desired switch on level by adjusting the LUX knob.

TIME SETTING:

The duration time is the length of time the circuit stays ‘on’ after activation. The duration time can be 

adjusted from 5 seconds to 40 minutes. Rotating the TIME knob from (+) to (-) will reduce the duration 

time. Note: Once the circuit has been triggered by the PIR sensor any subsequent detection will start 

the timed period again from the beginning.

SENSITIVITY SETTING (REACH):

The sensitivity set to (+) provides the maximum distance which PIR Sensor can be triggered by body 

movement. Turning the SENS knob from (+) to (-) will decrease both the sensitivity and activation zone.

Fig 2

RECESS MOUNT TO CEILING (Fig 2)

1. 

Unscrew the Cable Clamp, remove the Junction Box and Terminal Block.

2. 

Discard the Base piece for recess mount applications – not required

3. 

Connect circuit wiring to the terminal block as labelled

4. 

Refit the Terminal Block, Junction Box and Cable Clamp.

5. 

Fit springs, carefully lift the spring clips into the 82-88mm diameter hole, and recess the PIR to the   

 

ceiling. The spring clips will secure the unit. Refit the front cover.

Reviews: