OPERATION

With power applied, and a suitable load connected, the Cobra will be able to detect any moving infrared 

source. The unit has a number of detection zones, at various vertical and horizontal angles.

The Cobra has two adjustments on the underside of the sensor head as shown on Fig1.

Fig.1

The 

LUX

sensor. This adjustment can be set to allow the Cobra to operate the load at any light level between full 

daylight and almost complete darkness.

The 

TIME 

adjustment can be set for any period between 10 seconds and 15 minutes. This is the time that 

the lights will remain on after the last movement was detected. If movement is detected when lights were 

already on, the timer automatically restarts.

LOCATION

achieved when the sensor is at a height of 2.5m.

Avoid positioning the sensor where there are any sources of heat in the detection zone. Such sources

cause false activation under extreme conditions.

MOUNTING PROCEDURE

electrician.

Installation must be carried out according to local wiring rules (AS/N2S3000)

The Cobra is mounted as shown Fig.2.

Fig.2

MATELEC AUSTRALIA.  P 1800 281 282.  F  1300 281 282

[email protected].    WWW.MATELECAUSTRALIA.COM.AU

OVERRIDE

To actuate the override function, switch the light switch on/off/on in quick succession. This will allow

the light to be operated as a standalone unit without the sensor switching.