INSTRUCTIONS
1. Drain the coolant from the radiator.
2. Pre-mix the coolant with enough to fill the radiator.
3. Connect the conical adapter to the radiator filler neck.
4. Connect the shop air to the vacuum pump.
5. Connect the coolant hose to the tool’s main body, and put the other
end in the container with the pre-mixed coolant.
NOTE:
Figure 1 shows how the finished connection looks like.
6. Turn on the air valve to create a vacuum. When the gauge
reaches the range between 20 - 24 inHg, turn the air valve off.
7. Turn on the coolant valve to transfer the coolant into the cooling system.
8. Turn the coolant valve off when the gauge reading is 0 inHg.
9. Disconnect the air line.
10. Remove the tool from the cooling system.
11. Clean the tool prior to storage.
43014-INST
WARNING:
This product can expose you to chemicals including Di (2-ethylhexyl) phthalate, lead and lead compounds, which are known
to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.
ca.gov
1. FEATURES
2. SPECIFICATIONS
�
�
�
3. INSTRUCTIONS
CAUTION
Always read the instructions carefully before using the tool
Ensure the working area has adequate lighting
Keep children and unauthorized persons away from the working area
Keep working area clean and tidy, dry and free from unrelated materials
DO NOT allow untrained persons to use this tool kit
Always wear eye protection that meets OSHA and ANSI Z87.1 standards
Always wear gloves when working with the tool
Always wear ear protection
Disposal: Customers should follow local regulations to handle used/wasted parts
•
•
•
•
•
•
•
•
•
Set for refilling new coolant by creating a vacuum in cooling system
No need to undergo the time-consuming air bleeding after refilling new coolant
Conical adapter offers a wide application to different radiator filler necks
1
2
3
4
5
6
7
8
9
Shop air connector
Air valve
Vacuum gauge
Coolant hose connector
Drain hose connector
Conical adapter
Coolant valve
Drain house
Coolant hose
1 2
5
4
3
6
8
7
9
1
2
3
4
5
6
7
8
Drain old coolant from radiator.
Prepare a pre-mixed coolant with adequate volume.
Connect the conical adapter to coolant filler neck.
Connect the vacuum pump to shop air.
Connect coolant hose to tool’s main body, and put the other
end in the container with pre-mixed coolant.
Figure 1 shows how the finished connection looks like.
Turn on air valve and start to create vacuum until the reading
falls in the red area, and then turn off the air valve.
Turn on the coolant valve and the coolant will be introduced
into the cooling system accordingly.
Fig. 1