![Matco Tools MAXIMUS2.0 User Manual Download Page 25](http://html1.mh-extra.com/html/matco-tools/maximus2-0/maximus2-0_user-manual_1739678025.webp)
20
MAXIMUS2.0
User's Manual
form.
5.6.2 Clear Trouble Code
Tap “Clear Trouble Code” function menu, the system will automatically
delete the currently existing trouble code.
Note: The trouble code will not disappear until the trouble was
completely cleared.
5.6.3 Read Data Stream
Tap “Read Data Stream” in function menu, the system will display data
stream items.
Fig. 5-19
To select certain data stream item, just tap
, then the selected item
will be activated and
will change into
.
To select all items of the current screen, tap “Select Page”, and then
tap “Con
fi
rm” to enter data stream reading interface. See Fig. 5-20.
To deselect all items, tap “unselect”.
Fig. 5-20
After selecting, tap “
Graphic
”, the system will display data changes in
waveform.
To start to record, tap “
Record
”; To stop reading, click “
Stop
”.
On data stream reading page, the following operations can be done:
Graphic
: Tap to select the desired datastream to be browsed, and
then tap it to view the waveform.
Record
: Tap to start recording diagnostic data for future playback and
view. The saved file follows the naming rule: It begins with vehicle
type, and then the record starting time and ends with .x431 (To
differentiate between
fi
les, please con
fi
gure the accurate system time).
The file is stored in “My Report” under
menu. For details on
playback operations, please refer to Chapter 5.7.1 “My Report”.
Reports
: To save the current data in text format.
Tap
to return to the function selection screen.
5.6.4 Special Function
This option allows you to detect whether the system parameters are
normal or not. It mainly includes: Injector test, fuel pump test, purge
control solenoid and so on.