Seite 4
The small comustion load is 4.5 kW for each burner
This results in the following
FLOW VALUES
:
Earthgas H,
E (G20)
0,48 m
3
/h
Earthgas L,
LL (G25)
0,55 m
3
/h
Liquid gas
(G30)
0,35 kg/h
The appliance is operated in full combustion with fixed nozzles without adjustment.
For the Combi Wok burner and the pilot flame the small combustion quantity is regulated for liquid gas with
fixed nozzles. For earthgas the nozzles are adjusted.
3.
Instruction of Users
The user must be instructed how to operate the appliance. The instruction for use must be kept to the user.
The user must be told that after construction changes in the room, which affects the combustion supply, the
operation control must be carried out.
4. Operation
4.1 Operation
Elements
Wall Ranges
Free standing Ranges
A = Armature for adjustment Combi Wok burner
B = Armature for adjustment Water Overflow
C = Armature for adjustment Water Cock
A = Armature for adjustment Combi Wok burner
B = Armature for adjustment Water Overflow
4.2 Start up Burner
¾
Before operation the main gas cock on the appliance must be opened.
¾
Then press the knob of the safety tap “A“ and turn same anti clockwise
¾
Keep the knob pressed in and ignite with ignition pistol the pilot flame.
¾
After pilot flame burns, knob “A“ must remain pressed in for 15-20 seconds. If after releasing knob ”A”
the pilot flame continues burning, then the appliance is operable.
¾
If the pilot flame goes out, you have to repeat the ignition process.
¾
Now turn gas valve handle “B” anti clockwise to the required position between full combustion and
small combustion.
Attention! Do not lean over main burner during ignition process. The high flames could lead to
burns.