background image

 

 

MW 8100

 

PORTABLE WELDING FUME EXTRACTOR 

MW 8100

 

2.3 Overall Dimensions  

Picture 2 – 

MW

 

8100

 

overall dimensions 

3.

 

G

ENERAL 

U

SE 

A

ND 

S

AFETY 

D

IRECTIONS

 

 

Never leave packing material (such as foam polystyrene, rivets, carton, wood and so on) within 
children reach, since it could be dangerous.  

 

Before connecting the system, make sure that the connection point to the supply mains, implies 
the presence of all necessary guards as foreseen by  the Standards in force; also make sure that 
the aforementioned connection point is compatible with the system supply mains. 

 

This  equipment  is  to  be  used  solely  according  to  the  purposes  for  which  it  was  expressly 
realized. Any other kind of use is to be considered as improper and dangerous. We are not liable 
for any damages due to an improper use of the equipment. 

 

Before  connecting  the  equipment,  make  sure  that  the  ratings  correspond  to  those  of  the  supply 
mains. 

 

Do  not  carry  out  maintenance  operations  when  the  machine  is  running  or  connected  to  the 
electric power source. During these operations  make absolutely sure to  disconnect  the machine 
from the power supply line. 

 

If  the  machine  does  not  operate  properly  DISCONNECT  IT  AND  LET  KNOW  THAT  IT’S 
OUT  OF  ORDER.  Apply  to  our  After-Sale  Service  for  repairing  it  and  ask  for  original  spare 
parts.  
The non-observance of what has been mentioned above could endanger the equipment safety. 

 

We  advise  the  use  of  this  machine  only  to  responsible  and  duly  qualified  staff  in  areas 
inaccessible to children. 

 

Should  you  decide  not  to  use  the  equipment  anymore,  we  recommend  you  to  disable  it  by 
disconnecting it from the supply mains and to dismantle it according to the regulations in force 
in your Country. 

 

In  case  of  accidental  fall  or  nasty  bumps,  do  not  use  the  machine  and  contact  our  After-Sale 
Service immediately since the equipment safety could be endangered. 

 

Work and keep the machine in a dry and sheltered place 

 

Do not disperse used filters in the environment but deliver them to firms 
specialized in removal according to regulations in force. 

 

 Dimension 

Measure 

280 mm 

342 mm 

534 mm 

60 mm 

 

Table 3 – 

MW

 

8100

 

 

overall dimensions 

 

 

Measure   Dimension 

280 mm 

342 mm 

534 mm 

60 mm 

 

 

Summary of Contents for MW 8100

Page 1: ...MW 8100 PORTABLE WELDING FUME EXTRACTOR MW 8100 USER MAINTENANCE MANUAL MW 8100 Portable Welding Fume Extractor 110V ...

Page 2: ...______________________________________________ 3 2 1 1 Highest Efficiency _______________________________________________________ 3 2 1 2 Low Noise Level ________________________________________________________ 3 2 1 3 Handiness _____________________________________________________________ 3 2 2 WORKING MODE ____________________________________________________________ 4 2 3 OVERALL DIMENSIONS ____...

Page 3: ...STICS 2 1 Technical data Weight kg 20 Motor Supply voltage Frequency V Hz 110 50 Motor Power W 1150 Capacity air flow rate m3 h 140 Total pressure mm H2O 2400 Noise Level dBA 73 Flexible Hose Length mm 60 3000 Filtering Surface m2 1 03 Activated Carbons Weight kg 2 Table 1 technical parameters 2 1 1 Highest Efficiency The high quality filtering materials of this machine make it possible to obtain ...

Page 4: ...rinth that prevents sparks from reaching the CARTRIDE filter part 4 picture 1 The air flow passes the CARTRIDE filter and then the cell with activated carbons part 6 picture 1 Inside the machine made up of a sturdy painted sheet steel there is the electric motor part 5 picture 1 picture 1 MW 8100 PARTS Pos Description 1 Nozzle with magnetized base 2 Flexible hose 60 L 3000 mm 3 Machine inlet flang...

Page 5: ...ectric power source During these operations make absolutely sure to disconnect the machine from the power supply line If the machine does not operate properly DISCONNECT IT AND LET KNOW THAT IT S OUT OF ORDER Apply to our After Sale Service for repairing it and ask for original spare parts The non observance of what has been mentioned above could endanger the equipment safety We advise the use of ...

Page 6: ...fter making sure that the ratings written in this booklet and on the machine correspond to those of the supply mains 5 Press the starting button placed on the machine side When it is in the position 1 a light inside the button will show that the machine is in its ON position picture 3 6 When suction is not needed any more press again the button position 0 The light in the button will die out pictu...

Page 7: ... were not damaged during transport otherwise contact our Reseller Place the flexible hose on the inlet flange of the machine and fasten it by means of the hose clamp Connect the power supply cable to the main electric grid after making sure that the supply voltage frequency are 110 V 50 Hz Use the machine as described in paragraph 3 1 Use direction Before connecting the machine to the main electri...

Page 8: ...e Filter The cartride filter is part no 4 of picture 1 1 Make sure that the machine is disconnected from the power supply mains Then loosen the clips of the cover front side reference fig 4 and open it 2 Unscrew the blade screw 3 Take away the bar 4 Take out the filter and insert the new one making sure that it is well inserted 5 Replace the bar in its original position 6 Screw the blade screw aga...

Page 9: ...ot purified enough Inefficacious action of filters Check their state and replace them ref to chapter 5 MAINTENANCE The machine does not develop a sufficient aspirating capacity Filters are clogged and dirty Check their state and replace them ref to chapter 5 MAINTENANCE Physical obstructions and or blockages Check whether there are any foreign bodies inside the hose Take them away The hose is brok...

Page 10: ...re 5 wiring diagram 8 DESCRIPTION OF STICKERS Picture 6 Sticker indicating that there are parts live inside the machine Picture 7 single phase motor Voltages 110 V Sticker indicating that the electric motor is single phase and that it has to be fed with 110 V MONOFASE 110 ...

Page 11: ...ag with 2 kg active carbons for portable filtration unit Model MW 8100 You are recommended to use original spare parts POS DESCRIPTION 1 Nozzle part 1 picture 1 2 Flexible hose 60 L 3000 mm part 2 picture 1 3 Filtering cartridge CARTRIDE filter part 4 picture 1 4 Refill bag with 2 kg activated carbons 5 Handle part 7 picture 1 6 Electric motor part 5 picture 1 ...

Page 12: ...ntative declares under our own responsibility that the product PORTABLE UNIT FOR FILTRATION OF FUMES MODEL MW 8100 To which this declaration is referred is in conformity to what prescribed in directives 2006 42 CE 2014 35 UE 2014 30 UE We further state that The manufacturing year is quoted on the label with EC mark placed on the machine The serial number of the machine is quoted directly on it ...

Page 13: ...MW 8100 PORTABLE WELDING FUME EXTRACTOR MW 8100 NOTES ...

Page 14: ...MW 8100 PORTABLE WELDING FUME EXTRACTOR MW 8100 NOTES ...

Page 15: ...PORTABLE WELDING FUMES FILTRATION UNIT SERIES MW 8100 NOTES ...

Page 16: ...MW 8100 PORTABLE WELDING FUME EXTRACTOR MW 8100 NOTES ...

Reviews: