2 SAFETY GUIDELINES AND WARNINGS
2.1
Warnings and symbols
Safety instructions and warnings are marked in this manual
and on the product by the following pictograms:
A
procedure,
circumstance,
etc.
which
deserves extra attention.
CAUTION
!
Special
information,
commands
and
prohibitions in order to prevent damage.
WARNING
A WARNING refers to possible injury to the
user or installer or significant material damage
to the Mass Combi Pro if the installer / user
does
not
(carefully)
follow
the
stated
procedures.
Read this manual before installation and use
This product has been declared conform the
EC directives and standards.
Degree of protection: IP23. The product is
protected against touch by fingers and water
spray < 60 degrees from vertical.
Safety class 1. This product must be provided
with an equipment grounding conductor to the
AC-output ground terminal
2.2
Use for intended purpose
1
The Mass Combi Pro is constructed as per the
applicable safety-technical guidelines.
2
Use the Mass Combi Pro only:
for the charging of batteries and the supply of
loads attached to these batteries, in permanent
systems;
for the conversion of battery DC voltage to AC
voltage;
when connected to a dedicated double pole circuit
breaker and RCD;
with fuses, protecting the Mass Combi Pro AC and
DC wiring;
in a technically correct condition;
in a closed, well-ventilated room, protected
against rain, moist, dust and condensation;
after observing the instructions in the
user’s
manual.
WARNING
NEVER connect shore power to the generator
input. This may result in an electric shock!
WARNING
Never use the Mass Combi Pro in situations
where there is danger of gas or dust explosion
or potentially flammable products!
3
Use of the Mass Combi Pro other than mentioned in
point 2 is considered to be inconsistent with the
intended purpose. Mastervolt does not hold itself liable
for any damage resulting from the above.
2.3
Organizational measures
The user must always:
h
ave access to the user’s manual;
be familiar with the contents of this manual. This
applies in particular to Chapter 2
“Safety Guidelines
and Measures
”.
2.4
Warning of special dangers
1
If the Mass Combi Pro is switched off during
maintenance and/or repair activities, it should be
secured
against
unexpected
and
unintentional
switching on:
Remove the AC supply.
Remove the connection to the batteries.
Be sure that others cannot reverse the measures
taken.
2
If maintenance and repairs are required, use only
original spare parts.
2.5
General safety and installation precautions
Do not expose the Mass Combi Pro to rain, snow,
spray, moisture, excessive pollution and condensing
circumstances. To reduce risk of fire hazard, do not
cover or obstruct the ventilation openings. Do not install
the Mass Combi Pro in a non-ventilated area,
overheating results.
The Mass Combi Pro must be provided with an
equipment grounding conductor to the AC-input ground
terminal. Grounding and all other wiring must comply
with local rules and regulations.
In case of fire, you must use a fire extinguisher which is
appropriate for electrical equipment.
Short circuiting or reversing polarity will lead to serious
damage to batteries, Mass Combi Pro and wiring.
Fuses between batteries and Mass Combi Pro cannot
prevent damage caused by reversed polarity and
warranty will be void.
Protect all DC wiring with a proper fuse, according to
the guidelines in this manual.
Connection and protection must be done in accordance
with local standards.
Do not work on the Mass Combi Pro or system if it is
still connected to a power source. Only allow changes
in your electrical system to be carried out by qualified
electricians.