Mastervolt Digital DC 10x10A User Manual Download Page 5

 
 
 
 
 
 

 

SAFETY GUIDELINES AND MEASURES 

 

EN / Digital DC 10x10A / October 2010 

 

5

 

 

2  SAFETY GUIDELINES AND MEASURES 

 

2.1 

WARNINGS AND SYMBOLS  

Safety instructions and warnings are marked in this 
manual by the following pictograms:  

 

CAUTION 

Special data, restrictions and rules with 
regard to preventing damage. 

 

WARNING 

A WARNING refers to possible injury to 
the user or significant material damage to 

the charger if the user does not (carefully) 
follow the procedures. 

 

A procedure, circumstance, etc which 
deserves extra attention. 

 
 

2.2 

USE FOR INTENDED PURPOSE  

1 The 

Digital DC 10x10A 

is constructed as per the 

applicable safety-technical guidelines.  

2 Use 

the 

Digital DC 10x10A 

only:  

 

in a technical correct condition; 

  in a closed, well-ventilated room, protected 

against rain, moist, dust and condensation;  

 

observing the instructions in the users manual.  

 

WARNING 

Never use the Digital DC 10x10A in 
locations where there is danger of gas or 

dust explosion or potentially flammable 
products!  

 

3  Use of the 

Digital DC 10x10A 

other than 

mentioned in point 2 is not considered to be 
consistent with the intended purpose. Mastervolt 
is not liable for any damage resulting from the 
above.  
 

2.3 

ORGANIZATIONAL MEASURES  

The user must always:  

 

have access to the user's manual;  

 

be familiar with the contents of this manual. This 
applies in particular to this chapter, Safety 
Guidelines and Measures.  

 

2.4 

MAINTENANCE AND REPAIR  

1  If the electrical installation is switched off during 

maintenance and/or repair activities, it should be 
secured against unexpected and unintentional 
switching on:  

 

switch off all charging systems;  

 

switch off the connection with the batteries;  

  be sure that third parties cannot reverse the 

measures taken.  

2  If maintenance and repairs are required, only 

use original spare parts.  

 

2.5 GENERAL 

SAFETY 

AND 

INSTALLATION 

PRECAUTIONS  

  Connection and protection must be done in 

accordance with local standards.  

  Do not work on the 

Digital DC 10x10A 

or system 

if it is still connected to a current source. Only 
allow changes in your electrical system to be 
carried out by qualified electricians.  

  Check the wiring at least once a year. Defects 

such as loose connections, burned cables etc. 
must be corrected immediately.  

 
 

Summary of Contents for Digital DC 10x10A

Page 1: ...tal DC 10x10A MasterBus DC Switching Device MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 www Mastervolt com Copyright 2010 Mastervolt v 1 6 Octob...

Page 2: ...atus signal MasterBus menus Monitoring menu History menu to keep track of data Configuration menu to enter Digital DC 10x10A settings Alarm menu which shows an Overload and No Load situation of a chan...

Page 3: ...ions 12 5 4 Wire check 13 5 5 Event configuration 14 5 6 MasterBus Event data 14 5 7 MasterBus logical blocks 15 5 8 Dimming 18 5 9 Event examples Switches 18 6 INSTALLATION 19 6 1 Things you need for...

Page 4: ...his manual at a secure place 1 2 GUARANTEE SPECIFICATIONS Mastervolt guarantees that this unit has been built according to the legally applicable standards and specifications Should work take place wh...

Page 5: ...other than mentioned in point 2 is not considered to be consistent with the intended purpose Mastervolt is not liable for any damage resulting from the above 2 3 ORGANIZATIONAL MEASURES The user must...

Page 6: ...Bus position MasterBus controls up to 10A of the output Manual override Always On Hardware fused Manual override Always Off WARNING Manual Override overrides light voltage settings refer to sections 5...

Page 7: ...ntrol of the connected devices Mastervolt offers a wide range of panels which show full status information of your electrical system at a glance and a push of a button Three different panels are avail...

Page 8: ...network Do not make ring networks The electric power for the network is supplied by the connected MasterBus devices At least one device in the network should have powering capabilities see specificat...

Page 9: ...k has dropped below 10V 20V in a 12V 24V system for more than 30 seconds an alarm will be raised The alarm stops as soon as the battery voltage is higher than 11 22 V in a 12 24 V system for more than...

Page 10: ...ting see section 3 2 Application navigation lights and ceiling lights 5 2 3 Light 24V See light 12V now for 24V lighting At a voltage supply of 12V the Light 24V mode is not convenient 5 2 4 Switched...

Page 11: ...low value can be set in this mode See also section 5 3 8 5 2 10 Always On In Always On the channel does not switch off provided the hardware fuse current is not exceeded Application radio memory refri...

Page 12: ...DC was switched Off Disabled channel is not enabled power up Last Off On Last Disabled Intensity Voltage as percentage of the maximum output voltage 100 0 100 Maximum voltage Fixed maximum channel out...

Page 13: ...ch Convenient are the Switch Input 3 or 4 with LED buttons The Digital DC is able to illuminate a button LED when the load is switched On and it is working correctly This is possible only after config...

Page 14: ...vice you chose The command can be a section of the device to perform a task for example Channel 1 if the Digital DC is the target Select Selectable targets are system dependent Event 1 data Data trans...

Page 15: ...e function Disabled must be selected when the logical block is not used 5 7 2 Logical truth table For each of the three logical block sources one of next options can be chosen True 1 and False 0 are f...

Page 16: ...ht until it reaches the end switch When the end switch is closed 1 the drive must stop Shown are three situations The roof is in open position the end switch is open 0 The roof is being closed the end...

Page 17: ...Function Source 1 Source 2 Source 3 Result description AND Close roof End sw open True Only if the motor switch is on Close roof AND the End switch is open Roof is closed is TRUE In the next event Roo...

Page 18: ...Off 0 5 sec Dimming till button release 5 9 EVENT EXAMPLES SWITCHES 5 9 1 Event example 1 Main switch In this example the main system switch Switch 4 disables two Digital DC s Event configuration exam...

Page 19: ...se isolated tools Materials Digital DC 10x10A Up to ten fuses together maximum 100A per Digital DC See section 3 2 10 2 fuses 15A included see figure 1 MasterBus cable Terminator for MasterBus One tra...

Page 20: ...n MasterBus power is needed 1 DC In positive line 2 DC In negative line 3 Hardware fuses with two positions each 4 DC Output 1 5 Positive at the left Negative at the right For connecting the cables se...

Page 21: ...Digital DC input 6 7 MASTERCONNECT The Digital DC 10x10A belongs to the MasterConnect range These devices link to each other on the DC connectors directly by pushing them together and bolt them See f...

Page 22: ...on is pressed The reading light can now be switched On and Off by pressing the button shortly If configured long button presses let the light grow and dim alternately 7 2 SYSTEM EXAMPLE 1 CAMPER Figur...

Page 23: ...Off means the channels outputs are disabled except for the Always On outputs These outputs see also section 3 2 will stay active even when the Digital DC is disabled useful for a radio memory or refr...

Page 24: ...mble MasterBus cables Delivery includes 100m 330ft UTP cable 50 pcs modular jacks and crimping tool 77050100 100m 330ft MasterBus cable 77050200 50 pcs MasterBus connectors 77030900 Digital Input 7703...

Page 25: ...ide the 12V light voltage will change to the system voltage this can be 24V Make appropriate settings and change fuse position to Normal Position Wrong output voltage measured in one channel of Digita...

Page 26: ...e Digital DC 10x10A Unlimited MasterBus powering capacity Yes high powering Power consumption off board situation 2 mA 12V 2 mA 24V Communication isolation Galvanic Software layer MasterBus proprietar...

Page 27: ...7020400 Digital DC 10x10A Is in conformity with the provision of the EC EMC directive 89 336 EEC and amendments 92 31 EEC 93 68 EEC The following harmonised standards have been applied Generic emissio...

Page 28: ...Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 Email info Mastervolt com...

Reviews: