![Mastervolt Digital DC 10x10A User Manual Download Page 14](http://html1.mh-extra.com/html/mastervolt/digital-dc-10x10a/digital-dc-10x10a_user-manual_1739149014.webp)
MASTERBUS FUNCTIONS
14
October 2010 / Digital DC 10x10A / EN
5.5 EVENT
CONFIGURATION
Event Source
Event Target
Event Command
Event Data
MasterBus Switch
Digital DC
Channel 1
Toggle
Like mentioned in chapter 4, an event is a
condition
to be met at which you want
another device
to perform a
task
.
Shown below is the MasterBus Event configuration.
Events
Event 1 source
Select an event to serve as Event 1, for instance
Switch 1. If you don’t select Event 1, it stays Disabled.
Disabled
Event 1 target
Select a device in your system to perform the task if
Event 1 takes place. For instance the Digital DC.
Select… Selectable
targets
are system
dependent.
Event 1
command
Select a command, depending on the device you chose.
The command can be a section of the device to perform
a task, for example Channel 1 if the Digital DC is the
target.
Select… Selectable
targets
are system
dependent.
Event 1 data
Data translates the input into an output. See section 5.6.
Off
Off, On, Copy,
Copy Invert,
Toggle.
Event 2 to 63
Up to 63 events are configurable on the Digital DC.
5.6
MASTERBUS EVENT DATA
See figure 13.
Input (pulses)
The
input
can be achieved by operating an on/off
switch.
Output (data)
On
changes the status to On at the first signal.
Off
changes the status to Off at the first signal.
Copy
lets the status follow the input.
Copy Invert
lets the status follow the opposite of the
input. Copy is used for dimming too by holding the
pulse switch pressed for a longer time.
Toggle
changes the status at the first signal and
back at the second signal. It is used in combination
with a pulse switch.
Figure 13: Event data