Mastervolt Digital DC 10x10A User Manual Download Page 4

 
 
 
 
 
GENERAL INFORMATION 

 

 

 

4

 

 October 2010 / Digital DC 10x10A / EN 

 

1 GENERAL 

INFORMATION 

 

1.1 

USE OF THIS MANUAL 

Copyright © 2010 Mastervolt. All rights reserved. 
Reproduction, transfer, distribution or storage of part 
or all of the contents in this document in any form 
without the prior written permission of Mastervolt is 
prohibited. 
This manual serves as a guideline for the safe and 
effective operation, maintenance and possible 
correction of minor malfunctions of the 

Digital DC 

10x10A

, called Digital DC further in this manual

.

 

This manual is valid for the following model: 
 

Description 

Part number 

Digital DC 10x10A 

77020400 

 
It is therefore obligatory that every person who 
works on or with the 

Digital DC 

is completely familiar 

with the contents of this manual, and that he/she 
carefully follows the instructions contained herein. 
Installation of, and work on the 

Digital DC

, may be 

carried out only by qualified, authorised and trained 
personnel, consistent with the locally applicable 
standards and taking into consideration the safety 
guidelines and measures (chapter 2 of this manual).  
Keep this manual at a secure place! 
 

1.2 

GUARANTEE SPECIFICATIONS  

Mastervolt guarantees that this unit has been built 
according to the legally applicable standards and 
specifications. Should work take place which is not 
in accordance with the guidelines, instructions and 
specifications contained in this users manual, then 
damage may occur and/or the unit may not fulfil its 
specifications. All of these matters may mean that 
the guarantee becomes invalid. 
 

1.3 QUALITY 

 

During their production and prior to their delivery, all 
of our units are exhaustively tested and inspected. 
The standard guarantee period is two years.  
 

1.4 

VALIDITY OF THIS MANUAL  

All of the specifications, provisions and instructions 
contained in this manual apply solely to standard 
versions of the 

Digital DC 10x10A 

delivered by 

Mastervolt. 
 

1.5 LIABILITY 

 

Mastervolt can accept no liability for:  

 

consequential damage due to use of the 

Digital 

DC

;  

  possible errors in the manuals and the results 

thereof.  

 

CAREFUL! 

Never remove the type number plate. 
 

Important technical information required for service, 
maintenance & secondary delivery of parts can be 
derived from the type number plate.  
 

1.6 

CHANGES TO THE DIGITAL DC 10X10A  

Changes to the 

Digital DC 

may be carried out only 

after obtaining the written permission of Mastervolt. 
 

 

Summary of Contents for Digital DC 10x10A

Page 1: ...tal DC 10x10A MasterBus DC Switching Device MASTERVOLT Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 www Mastervolt com Copyright 2010 Mastervolt v 1 6 Octob...

Page 2: ...atus signal MasterBus menus Monitoring menu History menu to keep track of data Configuration menu to enter Digital DC 10x10A settings Alarm menu which shows an Overload and No Load situation of a chan...

Page 3: ...ions 12 5 4 Wire check 13 5 5 Event configuration 14 5 6 MasterBus Event data 14 5 7 MasterBus logical blocks 15 5 8 Dimming 18 5 9 Event examples Switches 18 6 INSTALLATION 19 6 1 Things you need for...

Page 4: ...his manual at a secure place 1 2 GUARANTEE SPECIFICATIONS Mastervolt guarantees that this unit has been built according to the legally applicable standards and specifications Should work take place wh...

Page 5: ...other than mentioned in point 2 is not considered to be consistent with the intended purpose Mastervolt is not liable for any damage resulting from the above 2 3 ORGANIZATIONAL MEASURES The user must...

Page 6: ...Bus position MasterBus controls up to 10A of the output Manual override Always On Hardware fused Manual override Always Off WARNING Manual Override overrides light voltage settings refer to sections 5...

Page 7: ...ntrol of the connected devices Mastervolt offers a wide range of panels which show full status information of your electrical system at a glance and a push of a button Three different panels are avail...

Page 8: ...network Do not make ring networks The electric power for the network is supplied by the connected MasterBus devices At least one device in the network should have powering capabilities see specificat...

Page 9: ...k has dropped below 10V 20V in a 12V 24V system for more than 30 seconds an alarm will be raised The alarm stops as soon as the battery voltage is higher than 11 22 V in a 12 24 V system for more than...

Page 10: ...ting see section 3 2 Application navigation lights and ceiling lights 5 2 3 Light 24V See light 12V now for 24V lighting At a voltage supply of 12V the Light 24V mode is not convenient 5 2 4 Switched...

Page 11: ...low value can be set in this mode See also section 5 3 8 5 2 10 Always On In Always On the channel does not switch off provided the hardware fuse current is not exceeded Application radio memory refri...

Page 12: ...DC was switched Off Disabled channel is not enabled power up Last Off On Last Disabled Intensity Voltage as percentage of the maximum output voltage 100 0 100 Maximum voltage Fixed maximum channel out...

Page 13: ...ch Convenient are the Switch Input 3 or 4 with LED buttons The Digital DC is able to illuminate a button LED when the load is switched On and it is working correctly This is possible only after config...

Page 14: ...vice you chose The command can be a section of the device to perform a task for example Channel 1 if the Digital DC is the target Select Selectable targets are system dependent Event 1 data Data trans...

Page 15: ...e function Disabled must be selected when the logical block is not used 5 7 2 Logical truth table For each of the three logical block sources one of next options can be chosen True 1 and False 0 are f...

Page 16: ...ht until it reaches the end switch When the end switch is closed 1 the drive must stop Shown are three situations The roof is in open position the end switch is open 0 The roof is being closed the end...

Page 17: ...Function Source 1 Source 2 Source 3 Result description AND Close roof End sw open True Only if the motor switch is on Close roof AND the End switch is open Roof is closed is TRUE In the next event Roo...

Page 18: ...Off 0 5 sec Dimming till button release 5 9 EVENT EXAMPLES SWITCHES 5 9 1 Event example 1 Main switch In this example the main system switch Switch 4 disables two Digital DC s Event configuration exam...

Page 19: ...se isolated tools Materials Digital DC 10x10A Up to ten fuses together maximum 100A per Digital DC See section 3 2 10 2 fuses 15A included see figure 1 MasterBus cable Terminator for MasterBus One tra...

Page 20: ...n MasterBus power is needed 1 DC In positive line 2 DC In negative line 3 Hardware fuses with two positions each 4 DC Output 1 5 Positive at the left Negative at the right For connecting the cables se...

Page 21: ...Digital DC input 6 7 MASTERCONNECT The Digital DC 10x10A belongs to the MasterConnect range These devices link to each other on the DC connectors directly by pushing them together and bolt them See f...

Page 22: ...on is pressed The reading light can now be switched On and Off by pressing the button shortly If configured long button presses let the light grow and dim alternately 7 2 SYSTEM EXAMPLE 1 CAMPER Figur...

Page 23: ...Off means the channels outputs are disabled except for the Always On outputs These outputs see also section 3 2 will stay active even when the Digital DC is disabled useful for a radio memory or refr...

Page 24: ...mble MasterBus cables Delivery includes 100m 330ft UTP cable 50 pcs modular jacks and crimping tool 77050100 100m 330ft MasterBus cable 77050200 50 pcs MasterBus connectors 77030900 Digital Input 7703...

Page 25: ...ide the 12V light voltage will change to the system voltage this can be 24V Make appropriate settings and change fuse position to Normal Position Wrong output voltage measured in one channel of Digita...

Page 26: ...e Digital DC 10x10A Unlimited MasterBus powering capacity Yes high powering Power consumption off board situation 2 mA 12V 2 mA 24V Communication isolation Galvanic Software layer MasterBus proprietar...

Page 27: ...7020400 Digital DC 10x10A Is in conformity with the provision of the EC EMC directive 89 336 EEC and amendments 92 31 EEC 93 68 EEC The following harmonised standards have been applied Generic emissio...

Page 28: ...Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Tel 31 20 3422100 Fax 31 20 6971006 Email info Mastervolt com...

Reviews: