![Mastervolt 44310750 User Manual Download Page 25](http://html1.mh-extra.com/html/mastervolt/44310750/44310750_user-manual_1738960025.webp)
25
5.2.10 Events
Value
Meaning
Factory setting
Adjustable. Range
Events
Event x source
Event-based command
Event by the ChargeMaster Plus that should result in an
action by another device on the
MasterBus
network.
Disabled
(See List of event
sources, section
5.2.11)
Event x target
Event-based command
Selection of device on the
MasterBus
network that
should take action due to an event by the ChargeMaster
Plus.
(See Device list)
Event x command
Event-based command
Action to be taken by the selected device.
(See
List of event
commands
in the
manual of the
selected device,)
Event x data
Event-based command
Value of the action to be taken by the selected device.
(See
List of event
commands
in the
manual of the
selected device,)
Event x+1
The next event appears after enabling Event x.
Disabled
See Event x.
5.2.11 Events source
The
ChargeMaster Plus
can be configured as an
event source
; an event source can be used to initiate an
event command
and
an
event action by another device
that is connected to the MasterBus.
Event sources
Description
Device state
State of the ChargeMaster Plus serves as a event source
Bulk
Bulk state of charge serves as an event source
Abs
Absorption state of charge serves as an event source
Float
Float state of charge serves as an event source
Figure 8: Meaning of the event data.
Input
(pulses)
The input is represented by an on/off switch.
Output
(data)
On
changes the status to On at the first signal.
Off
changes the status to Off at the first signal.
Copy
lets the status follow the input.
Copy Invert
lets the status follow the opposite of the input
Copy
is used for dimming too by holding the pulse switch
pressed for a longer time.
Toggle
changes the status at the first signal and back at
the second signal. It is used in combination with a pulse
switch.