![Mastervolt 44310750 User Manual Download Page 20](http://html1.mh-extra.com/html/mastervolt/44310750/44310750_user-manual_1738960020.webp)
20
1
If all wiring is OK, place the DC-fuse(s) to connect the
batteries to the ChargeMaster Plus.
WARNING
When placing this fuse, a spark can occur,
caused by the capacitors used in the
ChargeMaster Plus. This is particularly
dangerous
in
places
with
insufficient
ventilation, due to the gassing of the batteries
an explosion can occur. Avoid having
flammable materials close by.
2
Switch on the AC power supply
3
Hold the MODE button (Figure 2) pressed for 3
seconds to switch on the charger
Now the ChargeMaster Plus will initiate the charging
process.
4.9.3
MasterBus (optional)
During first commissioning the ChargeMaster Plus will be
recognized by the MasterBus network automatically.
Some settings can only be changed via the MasterBus
interface. See section 5.2 for an overview of all available
MasterBus settings. Refer to the use
r’s manual of the
remote control panel to change these settings.
4.10 DECOMMISSIONING
If it is necessary to put the ChargeMaster Plus out of
operation, follow the instructions in order of succession as
described below:
1
Switch the ChargeMaster Plus to stand-by (see
chapter 3).
2
Remove the DC-fuse(s) and disconnect the batteries.
3
Remove the AC-fuse(s) of the AC-input and/or
disconnect the AC-mains.
4
Open
the
connection
compartment
of
the
ChargeMaster Plus.
5
Check with a suitable voltage meter whether the
inputs and the outputs of the ChargeMaster Plus are
voltage free.
6
Disconnect all the wiring.
Now the ChargeMaster Plus can be demounted in a safe
way.
4.11 STORAGE AND TRANSPORTATION
When not installed, store the ChargeMaster Plus in the
original packing, in a dry and dust free environment.
Always use the original packing for transportation. Contact
your local Mastervolt Service Centre for further details if
you want to return the apparatus for repair.
4.12 RE-INSTALLATION
To reinstall the ChargeMaster Plus, follow the instructions
as described in this chapter (chapter 4).