OPERATION

Hazardous voltage. Can shock, burn or

cause death. 

Do not handle a pump or pump motor with

wet hands or when standing on a wet or damp surface, or
in water.

1. Shaft seal depends on water for lubrication. Do not

operate the pump unless it is in water as the seal may
be damaged if allowed to run dry.

2. The motor is equipped with an automatic reset ther-

mal protector. If the temperature in the motor should
rise unduly, the switch will cut off all power before
damage can be done to the motor. When the motor
has cooled sufficiently, the switch will reset automati-
cally and restart the motor. If the protector trips
repeatedly, remove the pump and check it as to the
cause of difficulty. Low voltage, long extension cords,
clogged impeller, very low head or lift, etc., could
cause cycling.

3. The pump will not remove all water. If the pump is

operating and suddenly no water comes out of the
discharge hose, shut off the unit immediately. The
water level is probably very low and the unit has bro-
ken prime.

NOTICE: 

For continuous operation, water must flow

through pump to prevent the motor from overheating.
The pump is cooled by the water flowing through the
housing.

4. This pump is designed to pump cold water only.

Pumping heated liquids can overheat the motor and
cause the thermal overload to trip. 

5. Pump can run in water that doesn’t completely cover

the motor housing, but the inlet must be completely
submerged or it will break suction and will not move
any water.

6. Keep the inlet screen clean at all times. If the bottom

surface of the pond or waterfall is dirty, raise the
pump slightly to reduce the amount of debris pulled
into the pump inlet.

7. If you need to reduce the flow, restrict the discharge.

Do not restrict the intake. Doing so will starve the
pump for water and can cause overheating.

MAINTENANCE

Risk of electric shock. Can burn or cause

death. 

Disconnect the power before servicing, repairing,

or working on pump.

The pump’s motor is completely sealed in the motor
housing and does not require any service. Disassembly
of the motor housing or modification or removal of the
power cord voids the warranty. The power cord is non-
replaceable.

Never run the pump dry! Running the pump dry can
damage the seal, causing leakage. This pump is a sub-
mersible type and must be in water at all times for prop-
er operation and cooling.

Periodically clean the suction screen. Make sure that
impeller rotation is not being hampered by any debris.

CUSTOMER HOTLINE: 1-877-455-5508

Summary of Contents for 62-3558-8

Page 1: ... MANUAL Submersible Pond Utility Pump PRINTED IN U S A 253P6060 1 23 03 62 3558 8 MD MD Installation Operation Parts For further operating installation or maintenance assistance Consumer Hotline 1 877 455 5508 ...

Page 2: ...e servic ing any component 8 Drain all water from the system before servicing 9 Secure the discharge line before starting pump An unsecured discharge line will whip possibly causing personal injury and or property damage 10 Check hoses for weak or worn condition before each use making certain that all connections are secure 11 Periodically inspect the pump and system compo nents Keep the screen fr...

Page 3: ...lows Restricting the suction will starve the pump for water and can damage the pump 4 If the pump is connected to a pond filter adjust the diverter valve to provide adequate flow to the filter Refer to the filter instruction manual to determine flow requirements of filter CUSTOMER HOTLINE 1 877 455 5508 PUMP CAPACITY Motor Minimum Pumps Motor Full Load Circuit Down H P Amps Req Amps To 1 6 1 5 15 ...

Page 4: ...y the water flowing through the housing 4 This pump is designed to pump cold water only Pumping heated liquids can overheat the motor and cause the thermal overload to trip 5 Pump can run in water that doesn t completely cover the motor housing but the inlet must be completely submerged or it will break suction and will not move any water 6 Keep the inlet screen clean at all times If the bottom su...

Page 5: ...ing caught in impeller Clean out impeller or replace pump Worn or defective parts or Clean impeller if plugged otherwise replace pump plugged impeller Check valve installed without Drill a 1 16 1 8 1 6 3 2 mm dia hole between pump discharge vent hole check valve Intermittent running Thermal overload tripped Protect the installation from the sun or pump stopped Pump cooler water automatically Check...

Page 6: ...se accident misapplication tampering alteration nor due to improper installation operation maintenance or storage nor to other than normal application use or service including but not limited to operational failures caused by corrosion rust or other foreign materials in the system or operation at pres sures in excess of recommended maximums as set forth in the owner s manual Requests for service u...

Page 7: ...ur étangs à usage général IMPRIMÉ AUX É U 253P6060 23 1 03 62 3558 8 MD MD Installation Fonctionnement Pièces Renseignements supplémentaires sur l utilisation l installation et l entretien de la pompe Assistance téléphonique 1 877 455 5508 ...

Page 8: ...n 9 Bien immobiliser la canalisation de refoulement avant de faire fonctionner la pompe Une canalisation de refoule ment non immobilisée risque de se déplacer comme un fouet et de causer des blessures corporelles et des dom mages matériels 10 Avant chaque utilisation s assurer que les tuyaux souples ne comportent pas de points faibles ni de parties usées et que tous les raccords sont bien serrés 1...

Page 9: ...ur de façon que le débit vers le filtre soit adéquat Se reporter au guide d utilisation livré avec le filtre pour déterminer le débit adéquat vers le filtre SERVICE D INFORMATION 1 877 455 5508 3388 0399 Use foliage to cover tubing to waterfall Diverter valve Power cord GFCI outlet Raise the pump off of the bottom of the pond Plastic tubing to waterfall Landscaping rocks Figure 1 Installation type...

Page 10: ...froidie par l eau qui la traverse 4 Cette pompe est conçue pour ne pomper que de l eau froide Le pompage de liquides chauds risque de faire surchauffer le moteur et de causer le déclenchement du dispositif de protection contre les surcharges 5 La pompe peut fonctionner même si l eau ne couvre pas complètement le carter du moteur Toutefois la bouche d entrée doit toujours être complètement immergée...

Page 11: ...rbine sont usées ou Nettoyer la turbine si elle est bouchée sinon remplacer la pompe défectueuses ou bien la turbine est bouchée Un clapet de non retour a été posé mais Percer un trou de 1 16 à 1 8 de pouce 1 6 à 3 2 mm de diamètre entre le un trou d aération n a pas été prévu tuyau de refoulement de la pompe et le clapet de non retour Fonctionnement Le dispositif de protection contre les Protéger...

Page 12: ...retenue ou entreposée d une façon inadéquate de plus la garantie sera aussi nulle et non avenue si la pompe est utilisée contrairement aux possibilités d utilisation normales si elle fait défaut à la suite de la forma tion de corrosion ou de rouille de l infiltration de toute matière étrangère ou si elle est employée d une façon telle qu elle excède les limites maximales admissibles indiquées dans...

Reviews: