MasterCraft 62-3520-6 Owner'S Manual Download Page 8

Table des matières

2

Pour communiquer avec le service de la clientèle ou celui des pièces, composez le  1 (877) 455-5508

Page

Garantie..........................................................................................................2

Consignes de sécurité générales ......................................................................3

Fonctionnement ..............................................................................................3

Câblage...........................................................................................................3

Installation ......................................................................................................4

Recherche des pannes.....................................................................................5

Pièces de rechange  ........................................................................................6

Garantie à vie

Mastercraft garantit que l’article spécifié au titre de la présente garantie est exempt de défauts de fabrication et
de matériaux.
Si  la pompe fait défaut lors de son utilisation, elle sera réparée ou remplacée conformément aux clauses et
aux conditions indiquées ci-dessous. 
Clauses et conditions générales
Cette garantie est nulle en cas de force majeure ou si la pompe est exposée à la négligence, à un usage abusif,
à un accident, à une utilisation inappropriée, si elle a été modifiée ou trafiquée ou si elle a été installée, util-
isée, entretenue ou entreposée d’une façon inadéquate; de plus, la garantie sera aussi nulle et non avenue si la
pompe est utilisée d’une façon telle qu’elle excède les limites maximales admissibles indiquées dans le guide
d’utilisation
Pour profiter du service après-vente en vertu de la présente garantie, vous devez retourner la pompe au maga-
sin aussi tôt que vous vous rendez compte de la panne. Nous prendrons par la suite les mesures correctives
aussi rapidement que possible. 
La présente garantie stipule la totalité de nos obligations envers le client et prescrit le seul recours possible de
ce dernier si le produit venait à faire défaut. 

Summary of Contents for 62-3520-6

Page 1: ... PRINTED IN U S A 1000000947 1 4 02 62 3520 6 OWNER S MANUAL CONTRACTOR Submersible Sump Pump MD Installation Operation Parts For further operating installation or maintenance assistance Call 1 877 455 5508 ...

Page 2: ...lteration nor due to improper installation oper ation maintenance or storage nor to other than normal application use or service including but not lim ited to operational failures caused by corrosion rust or other foreign materials in the system or operation at pressures in excess of recommended maximums as set forth in the owner s manual Requests for service under this warranty shall be made by r...

Page 3: ...exceeds the pump s capacity electri cal or mechanical failure in the pump etc may prevent your pump from functioning normally To prevent possi ble water damage due to flooding consult your dealer about installing a secondary sump pump a DC backup sump pump and or a high water alarm See the Troubleshooting Chart in this manual for information about common sump pump problems and remedies For more in...

Page 4: ...AUTOMATIC FLOAT SWITCH 1 Install pump following installation and operating instructions 2 Automatic float switch is sealed and factory adjust ed for most home sumps Turn on water level is 10 12 254 305 mm above pump base Turn off water level is 4 6 102 152 mm 3 Be sure float clearance is at least 8 203 mm For best performance sump diameter must be 14 356 mm and sump depth must be 18 457 mm 4 Plug ...

Page 5: ...See Automatic Float Switch section Motor hums but flow Impeller jammed Unplug pump and unclog is reduced or no flow Plugged check valve Unplug pump and unclog Blocked screen Unplug pump and clean screen Line leak Unplug pump and repair Worn Impeller Unplug pump and replace pump impeller Defective motor Replace pump Runs continuously Plugged screen Unplug pump and clean screen Defective switch Repl...

Page 6: ... 1 PS17 98 3 Screw Pump Handle 1 14000 4 Float Bracket Handle 1 PS54 14SS 5 Upper Pump Housing Motor Assembly 1 6 Screw 10 24 UNC SS 1 U30 971SS 7 Nut Acorn 10 24 UNC SS 1 U36 203SS 8 Automatic Float Switch Assembly 1 PS117 123P 9 Hex Nut 1 U36 105SS 10 Screw Phillips Pan Head 1 4327 11 Housing Clamp 1 15146 12 Lower Pump Housing 1 13 Pump Screen 1 12924 Not available as a replacement part If moto...

Page 7: ...1 02 62 3520 6 GUIDE D UTILISATION Pompe d assèchement immergée D ENTREPRENEUR MD Installation Fonctionnement Pièces Renseignements supplémentaires sur l utilisation l installation et l entretien de la pompe Composez le 1 877 455 5508 ...

Page 8: ...ure ou si la pompe est exposée à la négligence à un usage abusif à un accident à une utilisation inappropriée si elle a été modifiée ou trafiquée ou si elle a été installée util isée entretenue ou entreposée d une façon inadéquate de plus la garantie sera aussi nulle et non avenue si la pompe est utilisée d une façon telle qu elle excède les limites maximales admissibles indiquées dans le guide d ...

Page 9: ...euses années lorsqu elles sont installées entretenues et utilisées adéquate ment Cependant dans certains cas panne de courant accu mulation de saleté ou débris inondation dont le débit dépasse la capacité de la pompe panne mécanique ou électrique interne de la pompe etc il est possible que la pomme ne fonctionne pas normalement Pour prévenir la possibilité de dégâts causés par l eau consultez le m...

Page 10: ...interrupteur automatique à flotteur est scellé hermé tiquement et la longueur de son cordon a été réglé à l usine en fonction de la plupart des fosses domestiques Le niveau d eau amorçant la pompe est de 10 à 12 po 254 305 mm au dessus du socle de la pompe Le niveau d eau commandant l arrêt de la pompe est de 4 à 6 po 102 152 mm 3 Assurez vous que le flotteur a un dégagement d au moins 8 po 203 2 ...

Page 11: ...omatique à flotteur Le moteur bourdonne mais Turbine coincée Débranchez la pompe et débouchez la le débit est limité ou nul Clapet de non retour bouché Débranchez la pompe et débouchez le Crépine bouchée Débranchez la pompe et nettoyez la crépine Fuite de conduite Débranchez la pompe et réparez la fuite Turbine usée Débranchez la pompe et remplacez la turbine Moteur défectueux Remplacez la pompe L...

Page 12: ...ation 1 PS17 98 3 Vis pour la poignée 1 14000 4 Poignée 1 PS54 14SS 5 Corps supérieur moteur 1 6 Vis de filetage UNC SS 10 24 1 U30 971SS 7 Écrou en forme de gland de filetage UNC SS 10 24 1 U36 203SS 8 Interrupteur automatique à flotteur 1 PS117 123P 9 Écrou hexagonale 1 U36 105SS 10 Vis Phillips à tête cylindrique bombée 1 4327 11 Collier de serrage 1 15146 12 Corps inférieure 1 13 Crépine 1 129...