MasterCraft 62-3520-6 Owner'S Manual Download Page 3

Safety / Operation

3

For parts or assistance, call customer service at 

1-877-455-5508

READ AND FOLLOW 
SAFETY INSTRUCTIONS!

This is the safety alert symbol.

When you see this

symbol on your pump or in this manual, look for

one of the following signal words and be alert to the
potential for personal injury!

warns about hazards that 

will 

cause seri-

ous personal injury, death or major property damage if
ignored.

warns about hazards that 

can 

cause seri-

ous personal injury, death or major property damage if
ignored.

warns about hazards that 

will or can

cause minor personal injury or property damage if
ignored.
The label 

NOTICE 

indicates special instructions which

are important but not related to hazards.
Make sure installation complies with all electrical/
plumbing codes.

Hazardous voltage. Can cause serious or

fatal electrical shock. Disconnect power to pump before
servicing.

If floor is wet, disconnect power at main electrical

service before  walking on it. Do not stand in water

or touch metal surfaces when switching circuit breaker
or removing/installing fuses.

Pump is equipped with a three-prong, grounding

cord and plug. Do not modify cord or plug. Plug

this unit into a 115 V outlet, on an individual branch cir-
cuit, with a Class A, 10 A GFCI (Ground Fault Circuit
Interrupter).

Do not use in explosive environments.

Pump only water with this pump.

Inspect sump pump

and system components monthly. Keep it free of debris
and foreign objects. Perform maintenance as required.

Risk of flooding. If a flexible discharge

hose is used, pump may move around in sump when
motor starts.

If it moves far enough so that switch hits

side of sump, switch may stick and prevent pump from
starting. Make sure pump is secured so it cannot move
around in sump.
Electrically powered sump pumps normally give many
years of trouble-free service when correctly installed,
maintained, and used. However, unusual circumstances
(interruption of power to the pump, dirt/debris in the
sump, flooding that exceeds the pump’s capacity, electri-
cal or mechanical failure in the pump, etc.) may prevent
your pump from functioning normally. To prevent possi-
ble water damage due to flooding, consult your dealer
about installing a secondary sump pump, a DC backup
sump pump, and/or a high water alarm. See the
“Troubleshooting Chart” in this manual for information
about common sump pump problems and remedies. 
For more information, call customer service at 1-877-
455-5508.

SPECIFICATIONS

Power Supply Required. ..............................115 V, 60Hz
Motor Duty ....................................................Continuous
Liquid Temperature (Maximum) ..................77° F (25° C) 
Individual Branch Circuit Required (minimum) .....10.0 A
Motor Full Load (maximum)....................................7.5 A
Discharge (Insert for 1 1/4" 
also included).....................................1 1/2" Slip Adapter

PERFORMANCE

OPERATION

Pump is equipped with an automatic float switch 
which starts pump when water level reaches 10 - 12"
(254 - 305 mm). Pump automatically turns off when
level drops to 4 - 6" (102 - 152 mm). 

GENERAL GUIDELINES 

Sump should be at least 18" (457 mm) deep. Diameter
of sump should be at least 14" (356 mm).

Check valve is built-in. If necessary to allow flowback
from discharge pipe to sump:

• Drill a 1/8" (3.2 mm) diameter hole in discharge

pipe 2" (50.8 mm) above the pump. Pump should be
installed below basement floor level.

Discharge Pipe: Pump is supplied with flexible connec-
tor that fits 1 1/2" PVC or ABS pipe. Adapter insert
allows use of 1 1/4" PVC or ABS pipe. PVC or ABS
adapters may be purchased to fit other discharge pipe
sizes.

ELECTRICAL

Hazardous voltage. Can cause severe or

fatal electrical shock.

Pump is supplied with a ground-

ing conductor and grounding attachment plug. To
reduce risk of electric shock, be certain that it is con-
nected only to a properly grounded, grounding type
receptacle.

Plug this unit into a 115 V AC, 60 Hz outlet located
within 8’ (26.2 m) of sump and hooked up to an indi-
vidual branch circuit with a Class A, 10 A GFCI
(Ground Fault Circuit Interrupter). For installation of
such a circuit, consult a licensed electrician. Ground
terminal on pump cord plug is provided for your protec-
tion. DO NOT REMOVE!

Total Discharge

5'

10'

15'

20'

25'

in Feet (m)

(1.5 m)

(3 m)

(4.6 m)

(6.1 m)

(7.6 m)

Capacity

6000

5040

3840

2340

0

in GPH (LPH)

(22,710) (19,076) (14,534) (8,857)

0

Summary of Contents for 62-3520-6

Page 1: ... PRINTED IN U S A 1000000947 1 4 02 62 3520 6 OWNER S MANUAL CONTRACTOR Submersible Sump Pump MD Installation Operation Parts For further operating installation or maintenance assistance Call 1 877 455 5508 ...

Page 2: ...lteration nor due to improper installation oper ation maintenance or storage nor to other than normal application use or service including but not lim ited to operational failures caused by corrosion rust or other foreign materials in the system or operation at pressures in excess of recommended maximums as set forth in the owner s manual Requests for service under this warranty shall be made by r...

Page 3: ...exceeds the pump s capacity electri cal or mechanical failure in the pump etc may prevent your pump from functioning normally To prevent possi ble water damage due to flooding consult your dealer about installing a secondary sump pump a DC backup sump pump and or a high water alarm See the Troubleshooting Chart in this manual for information about common sump pump problems and remedies For more in...

Page 4: ...AUTOMATIC FLOAT SWITCH 1 Install pump following installation and operating instructions 2 Automatic float switch is sealed and factory adjust ed for most home sumps Turn on water level is 10 12 254 305 mm above pump base Turn off water level is 4 6 102 152 mm 3 Be sure float clearance is at least 8 203 mm For best performance sump diameter must be 14 356 mm and sump depth must be 18 457 mm 4 Plug ...

Page 5: ...See Automatic Float Switch section Motor hums but flow Impeller jammed Unplug pump and unclog is reduced or no flow Plugged check valve Unplug pump and unclog Blocked screen Unplug pump and clean screen Line leak Unplug pump and repair Worn Impeller Unplug pump and replace pump impeller Defective motor Replace pump Runs continuously Plugged screen Unplug pump and clean screen Defective switch Repl...

Page 6: ... 1 PS17 98 3 Screw Pump Handle 1 14000 4 Float Bracket Handle 1 PS54 14SS 5 Upper Pump Housing Motor Assembly 1 6 Screw 10 24 UNC SS 1 U30 971SS 7 Nut Acorn 10 24 UNC SS 1 U36 203SS 8 Automatic Float Switch Assembly 1 PS117 123P 9 Hex Nut 1 U36 105SS 10 Screw Phillips Pan Head 1 4327 11 Housing Clamp 1 15146 12 Lower Pump Housing 1 13 Pump Screen 1 12924 Not available as a replacement part If moto...

Page 7: ...1 02 62 3520 6 GUIDE D UTILISATION Pompe d assèchement immergée D ENTREPRENEUR MD Installation Fonctionnement Pièces Renseignements supplémentaires sur l utilisation l installation et l entretien de la pompe Composez le 1 877 455 5508 ...

Page 8: ...ure ou si la pompe est exposée à la négligence à un usage abusif à un accident à une utilisation inappropriée si elle a été modifiée ou trafiquée ou si elle a été installée util isée entretenue ou entreposée d une façon inadéquate de plus la garantie sera aussi nulle et non avenue si la pompe est utilisée d une façon telle qu elle excède les limites maximales admissibles indiquées dans le guide d ...

Page 9: ...euses années lorsqu elles sont installées entretenues et utilisées adéquate ment Cependant dans certains cas panne de courant accu mulation de saleté ou débris inondation dont le débit dépasse la capacité de la pompe panne mécanique ou électrique interne de la pompe etc il est possible que la pomme ne fonctionne pas normalement Pour prévenir la possibilité de dégâts causés par l eau consultez le m...

Page 10: ...interrupteur automatique à flotteur est scellé hermé tiquement et la longueur de son cordon a été réglé à l usine en fonction de la plupart des fosses domestiques Le niveau d eau amorçant la pompe est de 10 à 12 po 254 305 mm au dessus du socle de la pompe Le niveau d eau commandant l arrêt de la pompe est de 4 à 6 po 102 152 mm 3 Assurez vous que le flotteur a un dégagement d au moins 8 po 203 2 ...

Page 11: ...omatique à flotteur Le moteur bourdonne mais Turbine coincée Débranchez la pompe et débouchez la le débit est limité ou nul Clapet de non retour bouché Débranchez la pompe et débouchez le Crépine bouchée Débranchez la pompe et nettoyez la crépine Fuite de conduite Débranchez la pompe et réparez la fuite Turbine usée Débranchez la pompe et remplacez la turbine Moteur défectueux Remplacez la pompe L...

Page 12: ...ation 1 PS17 98 3 Vis pour la poignée 1 14000 4 Poignée 1 PS54 14SS 5 Corps supérieur moteur 1 6 Vis de filetage UNC SS 10 24 1 U30 971SS 7 Écrou en forme de gland de filetage UNC SS 10 24 1 U36 203SS 8 Interrupteur automatique à flotteur 1 PS117 123P 9 Écrou hexagonale 1 U36 105SS 10 Vis Phillips à tête cylindrique bombée 1 4327 11 Collier de serrage 1 15146 12 Corps inférieure 1 13 Crépine 1 129...

Reviews: