Safety / Operation
3
For parts or assistance, call customer service at
1-877-455-5508
READ AND FOLLOW
SAFETY INSTRUCTIONS!
This is the safety alert symbol.
When you see this
symbol on your pump or in this manual, look for
one of the following signal words and be alert to the
potential for personal injury!
warns about hazards that
will
cause seri-
ous personal injury, death or major property damage if
ignored.
warns about hazards that
can
cause seri-
ous personal injury, death or major property damage if
ignored.
warns about hazards that
will or can
cause minor personal injury or property damage if
ignored.
The label
NOTICE
indicates special instructions which
are important but not related to hazards.
Make sure installation complies with all electrical/
plumbing codes.
Hazardous voltage. Can cause serious or
fatal electrical shock. Disconnect power to pump before
servicing.
If floor is wet, disconnect power at main electrical
service before walking on it. Do not stand in water
or touch metal surfaces when switching circuit breaker
or removing/installing fuses.
Pump is equipped with a three-prong, grounding
cord and plug. Do not modify cord or plug. Plug
this unit into a 115 V outlet, on an individual branch cir-
cuit, with a Class A, 10 A GFCI (Ground Fault Circuit
Interrupter).
Do not use in explosive environments.
Pump only water with this pump.
Inspect sump pump
and system components monthly. Keep it free of debris
and foreign objects. Perform maintenance as required.
Risk of flooding. If a flexible discharge
hose is used, pump may move around in sump when
motor starts.
If it moves far enough so that switch hits
side of sump, switch may stick and prevent pump from
starting. Make sure pump is secured so it cannot move
around in sump.
Electrically powered sump pumps normally give many
years of trouble-free service when correctly installed,
maintained, and used. However, unusual circumstances
(interruption of power to the pump, dirt/debris in the
sump, flooding that exceeds the pump’s capacity, electri-
cal or mechanical failure in the pump, etc.) may prevent
your pump from functioning normally. To prevent possi-
ble water damage due to flooding, consult your dealer
about installing a secondary sump pump, a DC backup
sump pump, and/or a high water alarm. See the
“Troubleshooting Chart” in this manual for information
about common sump pump problems and remedies.
For more information, call customer service at 1-877-
455-5508.
SPECIFICATIONS
Power Supply Required. ..............................115 V, 60Hz
Motor Duty ....................................................Continuous
Liquid Temperature (Maximum) ..................77° F (25° C)
Individual Branch Circuit Required (minimum) .....10.0 A
Motor Full Load (maximum)....................................7.5 A
Discharge (Insert for 1 1/4"
also included).....................................1 1/2" Slip Adapter
PERFORMANCE
OPERATION
Pump is equipped with an automatic float switch
which starts pump when water level reaches 10 - 12"
(254 - 305 mm). Pump automatically turns off when
level drops to 4 - 6" (102 - 152 mm).
GENERAL GUIDELINES
Sump should be at least 18" (457 mm) deep. Diameter
of sump should be at least 14" (356 mm).
Check valve is built-in. If necessary to allow flowback
from discharge pipe to sump:
• Drill a 1/8" (3.2 mm) diameter hole in discharge
pipe 2" (50.8 mm) above the pump. Pump should be
installed below basement floor level.
Discharge Pipe: Pump is supplied with flexible connec-
tor that fits 1 1/2" PVC or ABS pipe. Adapter insert
allows use of 1 1/4" PVC or ABS pipe. PVC or ABS
adapters may be purchased to fit other discharge pipe
sizes.
ELECTRICAL
Hazardous voltage. Can cause severe or
fatal electrical shock.
Pump is supplied with a ground-
ing conductor and grounding attachment plug. To
reduce risk of electric shock, be certain that it is con-
nected only to a properly grounded, grounding type
receptacle.
Plug this unit into a 115 V AC, 60 Hz outlet located
within 8’ (26.2 m) of sump and hooked up to an indi-
vidual branch circuit with a Class A, 10 A GFCI
(Ground Fault Circuit Interrupter). For installation of
such a circuit, consult a licensed electrician. Ground
terminal on pump cord plug is provided for your protec-
tion. DO NOT REMOVE!
Total Discharge
5'
10'
15'
20'
25'
in Feet (m)
(1.5 m)
(3 m)
(4.6 m)
(6.1 m)
(7.6 m)
Capacity
6000
5040
3840
2340
0
in GPH (LPH)
(22,710) (19,076) (14,534) (8,857)
0