18
19
model no. 299-1978-8 | contact us 1-800-689-9928
M
AIN
TENAN
CE
Unplug the power cord (K).
6.
M
AIN
TENAN
CE
ITEM
DESCRIPTION/REASON
SERVICE
INTERVAL
Drain
the tank
Through normal operation of your air compressor, condensation
water will accumulate in the tank. To prevent corrosion of the
tank from the inside, condensation must be drainedat the end of
every workday. Be sure to wear protective goggles. Relieve the
air pressure in the system then open the drain valve on the
bottom of the tank to drain. user cold conditions it is especially
important to drain the tank after each use to reduce the chance
of problems resulting from the freezing of condensation water.
Check the
valve
Pull/activate the safety valve daily to ensure that it is operating
properly and to clear the valve of any possible obstructions.
Daily
Test for
leaks
Check that all connections are tight. Small leaks in the tank,
hoses, connections or transfer tubes will substantially reduce the
air compressor and tool performance. Spray a small amount of
soapy water around the area of suspected leaks with a spray
bottle. If bubbles appear: repair, replace or reseal the faulty
component. Do not over-tighten any connections.
Monthly
Storage
Before storing the air compressor, compressor:
• Drain tank (page 19).
• Use an air blow gun to clean all dust and debris from the
compressor.
• Disconnect and wind up the power cord.
•
Clean the ventilation openings on the motor enclosure with a
damp cloth.
• Drain all moisture from the tank.
• Pull the pressure safety valve to release all pressure from the
tank.
• Cover the entire unit to protect it from moisture and dust.
• Store the air compressor in a clean and dry location.
• In cold weather, store the compressor in a warm building when
it is not in use. This will reduce problems related to starting the
motor and the freezing of water condensation.
Prior to
storing
NOTE: Refer to instructions on how to drain tank (page 19).
Daily
Clean the
air filter
A dirty air filter will reduce air compressor performance and life.
To avoid contaminating the pump, the filter should be cleaned
frequently and replaced on a regular basis. Cean the foam filter
by immersing it in warm, soapy water. Dry thoroughly after.
Weekly
To check safety valve.
•
Before starting compressor, pull the ring on the safety valve (D) to make sure
that the safety valve operates freely. If the valve is stuck or does not operate
smoothly, contact a trained service technician.
To drain tank.
1.
Set the pressure switch (C) to the OFF position.
2.
3.
Turn air pressure regulator (E) counterclockwise to set the outlet pressure to zero.
4.
Pull and hold ring on safety valve (D), allowing air to bleed from the tank until air pressure is
minimized.
5.
Place suitable container under unit to catch water.
Slightly tilt unit and turn drain valve (I) counterclockwise to open.
7.
After the water has been drained, close the drain valve (I) (clockwise). The air compressor can now
be stored.
If any of the following symptoms appears while operating the product, stop using the product immediately
or serious personal injury could result. Only an authorized service centre should perform repairs on this
product.
WARNING!
Risk of bursting. Water will condense in the air tank. If not drained water will corrode and weaken the air
tank causing a risk of air tank rupture.
WARNING!
WARNING!
Risk of bursting. If the safety valve does not work properly, over-pressurization may occur causing air tank
rupture or an explosion.
NOTE:
Allow unit to cool before draining tank. Drain valves (R & Q) become hot during operation.
NOTE:
Troubleshooting problems may have similar causes and solutions.
Disconnect the electrical plug and disconnect any tools from air supply before attempting any adjustment.
NOTE: