This manual contains information that relates to protecting personal safety and preventing 
equipment problems. It is very important to read this manual carefully and understand it 
thoroughly before using this product. 

•  These precautions are intended for the personal safety of the operator and others working 

with the operator. Failure to follow these instructions may result in a permanent loss of vision, 
serious personal or even fatal injury, property damage and/or tool damage. Please take the time 
to read and understand them. 

•  Wear safety glasses with side shields when operating the pump and verify that others in the 

work area are also wearing safety glasses. Safety glasses must conform to both American 
National Standards Institute (ANSI Z87.1) and Canadian Standards Association (CSA Z94.3) 
standards requirements and must provide protection from flying particles from the front and the 
sides. Failure to comply may result in moderate injury.

•  The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The 

protector will reset itself once the motor cools down and an acceptable temperature has been 
reached. The pump may restart unexpectedly if it is plugged in. 

•  This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free 

service for a long time when properly installed, maintained, and used. However, inadequate 
electrical power to the pump, dirt, or debris may cause the pump to fail. Please carefully read 
the manual and follow the instructions regarding common pump problems and remedies.

•  Mastercraft Canada is not responsible for losses, injury, or death resulting from a failure to 

observe these safety precautions, or the misuse or abuse of pumps or equipment.

UNPACKING

•  Upon receiving the pump, it should be inspected for damage or shortages. If damage has 

occurred, file a claim immediately with the carrier that delivered the pump. If the manual is 
removed from the packaging, do not lose or misplace.

DANGER!

•  Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the presence 

of flammable or explosive vapours. Using this pump with or near flammable liquids can cause an explosion or fire, 
resulting in property damage, serious personal injury, and/or death.

•  ALWAYS disconnect the power to the pump before servicing. 
•  Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not 

disassemble the motor housing.

•  Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface or in water before 

disconnecting the power.

CAUTION!

•   Do not lift the pump by the power cord. 
•   Know the pump and its applications, limitations, and potential hazards. 
•   Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping the 

pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in premature failure.

•   Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, sand, and 

debris. Disconnect the pump from the power supply before inspecting. 

•   Follow all local electrical and safety codes, along with the National Electrical Code (NEC) and the Canadian Electrical 

Code (CEC). In addition, all Occupational Safety and Health Administration (OSHA) and Occupational Health and Safety 
(OH&S) guidelines must be followed. 

•   Ensure the electrical power source is adequate for the requirements of the pump.
•   Before using the pump, check the hose for holes or excess wear, which could cause leaks, and ensure the hose is not 

kinked or making sharp angles. A straight hose allows the pump to move the greatest amount of water quickly. Also 
check that all hose connections are tight to minimize leaks.

SAFETY GUIDELINES

SAFETY GUIDELINES

Summary of Contents for 062-3408-6

Page 1: ...IMPORTANT Please read this manual carefully before running this utility pump and save it for reference INSTRUCTION MANUAL 2 IN 1 SUBMERSIBLE UTILITY PUMP NON SUBMERSIBLE TRANSFER PUMP Model No 062 3408 6 ...

Page 2: ...headline bars continuation tabs notes warnings headline bars continuation tabs notes warnings ...

Page 3: ... follow them with use of this product TABLE OF CONTENTS Quick Start Guide 4 Technical Specifications 6 Safety Guidelines 8 Key Parts Diagram 11 Assembly Preparation 12 Assembly Instructions Submersible Utility Pump 13 Operating Instructions Submersible Utility Pump 14 Assembly Instructions Non submersible Transfer Pump 15 Operating Instructions Non submersible Transfer Pump 16 Maintenance 17 Troub...

Page 4: ... 19 mm garden hose thread connector has a rubber gasket to minimize water leaks The larger the inside diameter and the shorter the length of hose the less pressure that is lost or the larger the flow rate Place upright on a solid base The pump must be standing in at least 1 1 2 38 1 mm of water before you start it The shaft seal is water lubricated and may be damaged if the pump runs dry 3 4 19 mm...

Page 5: ...ear suction hose to the suction strainer Then place the strainer in at least 1 2 5 cm of water at the lowest point to be pumped 1 1 2 5 cm NOTE Place the strainer in at least 1 2 54 cm of water at the lowest point to be pumped Make sure the connection is airtight An air leak can cause the pump to run dry Always ensure the washer in the hose bib is not damaged An airtight seal is necessary for this...

Page 6: ... Discharge size 3 4 19 mm garden hose thread connection Seal Lip seal Cord length 10 3 m Single phase Permanent split capacitor PSC Motor protection Auto reset thermal overload protection in motor Maximum flow submersible 1600 U S GPH 6 056 L hr Maximum flow non submersible 950 U S GPH 3596 L hr Maximum head height 30 9 1 m MOTOR AND ELECTRICAL SKU number 062 3408 6 HP 1 4 Power 115 V AC Hz 60 RPM...

Page 7: ... 4 14 6 cm 3 4 NH thread 7 1 2 19 1 cm Lift in feet metres 0 0 m 5 1 5 m 10 3 m 15 4 6 m 20 6 m 25 7 6 m Submersible Utility Pump Function U S gallons litres per hour 1600 6 056 1500 5 678 1300 4 921 950 3 596 700 2 649 210 794 Non submersible Transfer Pump Function U S gallons litres per hour 950 3 596 840 3 179 730 2 763 600 2 271 400 1 514 170 643 ...

Page 8: ...PACKING Upon receiving the pump it should be inspected for damage or shortages If damage has occurred file a claim immediately with the carrier that delivered the pump If the manual is removed from the packaging do not lose or misplace DANGER Do not pump flammable or explosive liquids such as oil gasoline kerosene ethanol etc Do not use in the presence of flammable or explosive vapours Using this ...

Page 9: ...ol panel must be made in accordance with all applicable electric codes Do not use the power cable to lift pump WARNING Release all pressure and drain all water from the system before servicing any component Secure the discharge line before starting the pump An unsecured discharge line will whip possibly causing personal injury and or property damage Extension cords may not deliver sufficient volta...

Page 10: ...ltage and phase information stamped on the pump s identification plate matches the available power IDENTIFICATION PLATE Note the numbers on the pump s identification plate and record at the end of the manual for future reference INSULATION TEST Before the pump is put into service an insulation megger test should be performed on it The ohm values as well as the volts and amps should be recorded CAU...

Page 11: ...1 KEY PARTS DIAGRAM PARTS LIST No Description Qty 1 Power cord 1 2 Carry handle 1 3 Motor housing 1 4 Pump outlet 1 No Description Qty 5 Priming plug 1 6 Suction hose 1 7 Suction strainer 1 1 2 3 6 7 4 5 ...

Page 12: ... also used as a non submersible transfer pump It is suitable for draining or removing water from the following flooded area clogged sinks water beds water basins boats stock tanks etc This pump has not been tested or approved for use in swimming pools or in salt water marine areas This pump is not designed to function as a permanently installed sump pump It is also not engineered to be run continu...

Page 13: ...before attempting to install service or maintain the pump Never handle a pump with wet hands or when standing on wet or damp surface or in water Fatal electrical shock could occur Do not allow the plug to fall in water and do not stand in water while the pump is plugged in NOTE The larger the inside diameter and the shorter the length of hose the less pressure that is lost or the larger the flow r...

Page 14: ...he anti airlock hole eliminating the airlock so that the pump can operate properly If debris blocks the anti airlock hole unplug the pump clean out the anti airlock hole and restart the pump Alternately drain the water out of the garden hose keep the end of the hose out of the water and plug in the power cord restarting the pump OPERATION AIRLOCK CAUTION The anti airlock hole is for anti airlock p...

Page 15: ...void skin burns unplug the pump and allow time for it to cool after periods of extended use WARNING Always disconnect power source before attempting to install service or maintain the pump Never handle a pump with wet hands or when standing on wet or damp surface or in water Fatal electrical shock could occur Do not handle the pump or pump motor with wet hands or when standing on a wet or damp sur...

Page 16: ...ssary for this pump to operate Make sure the end of the outlet hose is not under water If the outlet is under water the pump may not work Do not coil or kink the hose If water is not pumping in 30 seconds unplug the power cord and check the connection on the two ends of the inlet hose to make sure there are no air leaks Then add water into the priming port again and repeat the process OPERATION Op...

Page 17: ...then plug the pump back into the grounded GFCI outlet Do not disassemble the motor housing This motor has NO repairable internal parts and disassembly may cause leakage or dangerous electrical wiring issues Do not lift up the pump by the power cord CAUTION Always use the handle to lift the pump Never use the power cord to lift the pump To avoid skin burns unplug the pump and allow time for it to c...

Page 18: ...PUMP FUNCTION Problem Possible Causes Corrective Action The pump does not start or run 1 The fuse is blown 2 The breaker is tripped 3 The plug is disconnected 4 The plug is corroded 5 The motor failed 1 Replace the fuse 2 Reset the breaker 3 Secure the plug 4 Clean the plug prongs 5 Replace the pump The pump does not prime 1 The suction line has an air leak 2 The impeller is clogged 3 Did not fill...

Page 19: ... damage is caused by repairs made or attempted by others i e persons not authorized by the manufacturer f this warranty will not apply to any product that was sold to the original purchaser as a reconditioned or refurbished product unless otherwise specified in writing g this warranty will not apply to any product or part thereof if any part from another manufacturer is installed therein or any re...