headline bars
continuation tabs
notes
warnings
13
• Attach a garden hose with a 3/4" (19 mm) garden hose thread (not included) to the pump
outlet.
• Place the pump on a solid base in flooded area or any place that you would like to remove
water. Plug the pump into a 115 V GFCI power outlet.
ASSEMBL
Y INSTRUCTIONS
SUBMERSIBLE UTILITY PUMP INSTALLATION
CAUTION!
• Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns, unplug the
pump and allow time for it to cool after periods of extended use.
WARNING
• Always disconnect power source before attempting to install, service, or maintain the pump. Never handle a pump
with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur.
• Do not allow the plug to fall in water and do not stand in water while the pump is plugged in.
NOTE:
• The larger the inside diameter and the shorter the length of hose, the less pressure that is lost (or the larger the
flow rate).
• Be sure the 3/4" (19 mm) garden hose thread connector has a rubber gasket to minimize water leaks.
• Place upright on a solid base.
• The pump must be standing in at least 1 1/2" (38.1 mm) of water before you start it. The shaft seal is water
lubricated and may be damaged if the pump runs dry.
3/4" (19 mm) NH
thread
1 1/2” (38.1 mm)