TCXO AND RTC CIRCUIT
The Display contains a
RTC (Real Time Clock)
circuit allowing
the clock to maintain an accuracy of ± minute per year to
the last known NTP input (± 165 mSec per day) when NTP
is not present or cannot be decoded (i.e. freewheeling
mode).
MAINTENANCE-FREE RECHARGEABLE BATTERY
The RTC is maintained continuously from a rechargeable
battery circuit during periods of power outage. Minimum
holdover period is two weeks with a fully-charged battery
under constant drain.
DEFAULT CONFIGURATION
The factory defaults may be restored by using the
WinDiscovery
program,
Telnet
or by using the reset button
at the rear of the NTDS-A.
Your Masterclock display ships from the factory with the
following configuration as defined below. The NTDS-A
firmware interprets incoming time signals as UTC.
SETTING
CONFIGURATION SELECTION
Disabled
Time Zone Offset
Disabled
Daylight Savings Time
Enabled
NTP Client with DHCP
Enabled
24 Hour format