Installation and Operating Instructions for  

 PURO PRO SC Series Modular 

 Reverse Osmosis Unit  

Model #:                                                             

 

_______ PURO PRO 1800 SC    1800 GPD RO System

 

 
Shipping Carton Description  / unit:
 

 

# of 

cartons 

Contents 

Description 

PURO PRO 
Module Frame 

Modular RO Assembly 

Filter Elements 
 

(6) RO Membranes 

Installation 
Accessories 

Inlet Solenoid, (1) Float Control, 
Check Valve, Rubber Gloves, 
Silicone Packets 

 
System Description:

                            

 

 

The PURO PRO is a modular reverse osmosis filtration system for 
the reduction of Total Dissolved Solids (TDS) from water.  The 
system consists in six (6) high-performance reverse osmosis 
membranes.  The system is designed to operate with a pressurized 
(40 to 90 psi) feed and a vented storage tank for collection of the 
product water.  An inlet normally-closed solenoid allows pressurized 
water to enter the system whenever it is activated by the level float 
which is installed in a water collection tank.  See Figure 1.  The 
modular assembly is constructed of non-corrosive Noryl

polypropylene, and FRP materials.  The reverse osmosis system is 
rated at a maximum working water pressure of 90 psi.  The system 
has a fixed inlet flow control, and an adjustable drain restrictor control 
for achieving maximum efficiency. 
                                

 
 
 
 
 

Summary of Contents for PURO PRO 1800 SC Series

Page 1: ...OPERATION MANUAL PURO PRO 1800 SC Series Modular Reverse Osmosis System MASTER Water Conditioning Corp www masterwater com September 2012 Version...

Page 2: ...nections 9 10 PURO PRO Power Switch Operation 10 11 PURO PRO Float Switch Operation 11 12 Filling the PURO PRO with Water and Start Up 13 PURO PRO Operation and Maintenance 13 14 Production Data Recor...

Page 3: ...d Solids TDS from water The system consists in six 6 high performance reverse osmosis membranes The system is designed to operate with a pressurized 40 to 90 psi feed and a vented storage tank for col...

Page 4: ...be correct Avoid using outlets that are switch controlled 2 Maximum amperage required is 5 amps 3 Make sure the electrical service provides power 24 hours per day We recommend installing a surge prot...

Page 5: ...3 Figure 1 Typical PURO PRO Installation...

Page 6: ...eservative 5 Ensure that the O Ring s on each housing and membrane has Silicone only Lubricant Do not use petroleum lubricants 6 Install two of the membranes in the top row 7 To install the membranes...

Page 7: ...rane Placing Membrane In Manifold Inserting Membrane Housing Into Manifold 8 Repeat with the second membrane in the middle row 9 Install the remaining membranes using the procedure from steps 7 and 8...

Page 8: ...6 Figure 2 Manifold Figure 3 Housings Pre Filter Manifold Post Filter Manifold 4 Membrane Manifolds Housing O Ring...

Page 9: ...O Positioning 1 Wall mount the PURO PRO There are holes drilled into the plastic housing to be used for wall mounting If using the PURO PRO on the ground make sure to place a support under the bottom...

Page 10: ...nnections Figure 5 1 Pipe Puro Pro into the service lines the inlet is NPT and the outlet is OD tube compression We recommend using an inlet outlet and bypass valve in installation piping for future s...

Page 11: ...when in the horizontal floating position See Figure 1 2 Connect the float switch to the power box with the electrical connector provided See Figure 6 3 The inlet solenoid is already connected to the...

Page 12: ...float switch is in the vertical position Whenever the storage tank is full the float switch is in the horizontal floating position the solenoid will be closed PURO PRO Power Switch Operation 1 The pow...

Page 13: ...is closed power is passed and the solenoid valve is opened allowing the Modular Pro to produce treated water 2 This function can be tested by holding the float adjusting the orientation and listening...

Page 14: ...12 Low Water Switch On High Water Switch Off WEIGHT METHOD Low Water Switch On High Water Switch Off ANCHOR POINT METHOD WEIGHT DEVICE...

Page 15: ...sure that the water level is as required Adjust the float rotation point as necessary PURO PRO Operation and Maintenance 1 To ensure proper maintenance it is recommended that a production data sheet b...

Page 16: ...14 6 If the module frame structure becomes loose tighten the FRP Bolts located at the frame corners...

Page 17: ...duct Quality Action Taken Product measurement criteria is selected based upon the configuration of the system For example an appropriate criteria may be gallons per hour or inches of tank height per h...

Page 18: ...have become severely fouled Replace and re start Symptom PURO PRO has greatly reduced production Possible Cause Solution Water pressure is decreased below 60 psi Restore water pressure Drain control...

Page 19: ...oid has failed Replace inlet solenoid Symptom Storage Tank Overflows Possible Cause Solution Float Switch has failed Replace float switch Inlet Solenoid has failed Replace the inlet solenoid PURO PRO...

Page 20: ...freezing or hot water All replacement filters and membranes must be Master Water Conditioning filters and membranes or the warranty is void If the unit is altered by anyone other than Master Water Co...