Table of Contents 

 

Page 

No. 

Topic 

Description 

Model #  

Model Number Information 

Component Packaging Description 

Packaging Description 

MP Logix Control Valve System 

System Description 

 

MP Softening System 

System Positioning 

Logix 255/762 Control Valve 

Attaching Valve to Tank 

Figure 1 & Figure 2 

 

Logix 255/762 Control Valve, Cont’d 

Attaching Valve to Tank 

Figure 1 & Figure 2, Cont’d 

Service & Drain Piping, 

General Installation Layout 

 

Drain Piping  

Information 

Service & Drain Piping, 

General Installation Layout 

Cont’d 

Drain Piping  

Figure 3, Cont’d 

System Schematic 

Piping Layout 

Electrical Supply 

Electrical Requirements 

Brine Tank / Brine Tubing 

Brine tank  

Logix 255/762 Control Valve Electrical 

Connection 

Instructions on Logix 762 

 Electrical Connection 

Filling Softener with Water 

Filling Softener with Water 

      

Filling Softener with Water 

Continued 

Details for Filling Softener Tank with Water 

Continued  

Logix 762 Control Valve Timer Settings 

Setting the Timer 

10 

 

Logix 762 Control Valve Timer Settings 

Continued 

Setting the Timer 

Continued 

Final Check 

Final Installation Check 

11 

Disinfection 

Disinfecting the Unit 

12 

Troubleshooting 

Symptom / Cause / Solution 

13 

Troubleshooting 

Symptom / Cause / Solution 

14 

Troubleshooting 

Symptom / Cause / Solution 

15 

ERR Troubleshooting 

Error Troubleshooting 

16 

255/762 Valve Body Schematic 

Parts View 

17 

Valve Body Parts List  

Part Numbers List 

18 

Logix Valve Parts List  

Part Numbers List 

19 

Warranty  

Warranty 

 

Summary of Contents for MP-MBA-15T

Page 1: ...Installation and Operation Manual MP MBA 15T 30T using the 255 762 Logix Control Valve July 2006 MASTER Water Conditioning Corp www masterwater com...

Page 2: ...ne Tank Brine Tubing Brine tank 7 Logix 255 762 Control Valve Electrical Connection Instructions on Logix 762 Electrical Connection 8 Filling Softener with Water Filling Softener with Water 9 Filling...

Page 3: ...r to initiate regeneration The Logix Valve is constructed of non corrosive Noryl material and is rated at a maximum working water pressure of 100 psi This softener includes a manually operated bypass...

Page 4: ...ar enough from walls and other obstructions to allow for servicing the unit 2 Place the water softener within reasonable access to a grounded 115V 60 HZ circuit and a legal drain line connection Logix...

Page 5: ...s of the control valve are 3 4 copper or pvc and are located on the back of the valve body As you face the timer the inlet is on the left and the outlet is on the right Always follow local plumbing co...

Page 6: ...Maximum drain line height is 6 feet above the control valve The drain line must be piped to an open air gap See Figure 3 Always follow local plumbing codes UNDER NO CIRCUMSTANCES SHOULD THERE BE A DIR...

Page 7: ...or water meter if its public water supply Master Water Conditioner Brine tank Air Gap Drain Overflow fitting to floor drain gravity Treated water Untreated to outside 224 Shoemaker Rd Pottstown PA 19...

Page 8: ...mps 3 Make sure the electrical service provides power 24 hours per day We recommend installing a surge protector to protect unit from power surges which are not covered by warranty Brine Tank 1 The br...

Page 9: ...already installed at the factory 1 Remove plastic control valve cover by spreading sides while lifting 2 Plug transformer into back of timer following existing wires 3 Plug transformer into a properly...

Page 10: ...L THE RESIN WILL BE FLUSHED TO DRAIN DURING START UP 2 When water is running steadily at the drain open the bypass valve s inlet and outlet to their maximum position 3 Simultaneously press the SET and...

Page 11: ...ss the SET button The screen will show the Day of Week in blinking triangle 2 To change the Day of Week use the UP or DOWN arrows 3 Press the SET button Time of Regeneration Setting the factory defaul...

Page 12: ...use the UP or DOWN arrows 3 Press the SET button Note The screen will now flash between flow rate and gallons remaining until next regeneration If water was tested by Master Water Conditioning follow...

Page 13: ...11...

Page 14: ...ual bypass valve Leak at riser pipe seal Insure that riser pipe is properly sealed at o ring seal Inspect pipe for cracks Insufficient brine Check brine float height and clean assembly if necessary Ch...

Page 15: ...o height of valve Damaged valve disk Replace all valve disks Partially restricted drain line Remove restriction Symptom Insufficient Refill to Brine Tank Possible Cause Solution Brine refill control R...

Page 16: ...ral bed with cleaner Slots in riser pipe or laterals are filled with resin fines Inspect and clean distributor pipe slots as needed Symptom Salt in Water to Service After Regeneration Possible Cause S...

Page 17: ...15...

Page 18: ...16...

Page 19: ...17...

Page 20: ...18...

Page 21: ...l be void in the event of damages from external sources or where the conditioner has been operated at pressure in excess of 100 pounds per square inch or at a temperature greater than 100 degrees F or...