Filling Water Softener with Water: 

Figure 4 

 

 

1.  Push the FOR REGENERATION button 

(Figure 4)

 on the 

controller down for 5 seconds. This will initiate a manual 
regeneration. You will notice a flashing hour glass during 
regeneration.  

    The controller will indicate that the motor is turning the camshaft 
     to cycle C1 (BACKWASH). The controller will indicate the total  
     regeneration time remaining. Filling tank in this position allows air 
     to escape from drain. 

Open the bypass inlet valve ¼ turn and allow water to flow into the 
mineral tank at a slow rate.  

Warning:  IF WATER ENTERS THE TANK TOO FAST, ALL THE 
RESIN WILL BE FLUSHED TO DRAIN DURING START UP. 

2.  When water is running steadily at the drain, open the bypass 

valve’s inlet and outlet to their maximum position. 

3.  Simultaneously press the SET and UP buttons on the controller 

for 1 second then release, the motor will advance the cam to C2.  
Once C2 is displayed simultaneously press the SET and UP 
buttons on the controller for 1 second then release, the motor will 
advance the cam to C3.  Repeat this procedure until the timer 
enters the C7 (FAST RINSE) position.  The softener will go 
through the rinsing cycle and then automatically advance to 
(BRINE REFILL) C8 and fill the brine tank with the proper amount 
of water.  

4.  The control valve will advance to C0 (REGENERATION 

COMPLETE) and Time of Day will be displayed.  This is  

     treated water. 

Summary of Contents for MP-MBA-15T

Page 1: ...Installation and Operation Manual MP MBA 15T 30T using the 255 762 Logix Control Valve July 2006 MASTER Water Conditioning Corp www masterwater com...

Page 2: ...ne Tank Brine Tubing Brine tank 7 Logix 255 762 Control Valve Electrical Connection Instructions on Logix 762 Electrical Connection 8 Filling Softener with Water Filling Softener with Water 9 Filling...

Page 3: ...r to initiate regeneration The Logix Valve is constructed of non corrosive Noryl material and is rated at a maximum working water pressure of 100 psi This softener includes a manually operated bypass...

Page 4: ...ar enough from walls and other obstructions to allow for servicing the unit 2 Place the water softener within reasonable access to a grounded 115V 60 HZ circuit and a legal drain line connection Logix...

Page 5: ...s of the control valve are 3 4 copper or pvc and are located on the back of the valve body As you face the timer the inlet is on the left and the outlet is on the right Always follow local plumbing co...

Page 6: ...Maximum drain line height is 6 feet above the control valve The drain line must be piped to an open air gap See Figure 3 Always follow local plumbing codes UNDER NO CIRCUMSTANCES SHOULD THERE BE A DIR...

Page 7: ...or water meter if its public water supply Master Water Conditioner Brine tank Air Gap Drain Overflow fitting to floor drain gravity Treated water Untreated to outside 224 Shoemaker Rd Pottstown PA 19...

Page 8: ...mps 3 Make sure the electrical service provides power 24 hours per day We recommend installing a surge protector to protect unit from power surges which are not covered by warranty Brine Tank 1 The br...

Page 9: ...already installed at the factory 1 Remove plastic control valve cover by spreading sides while lifting 2 Plug transformer into back of timer following existing wires 3 Plug transformer into a properly...

Page 10: ...L THE RESIN WILL BE FLUSHED TO DRAIN DURING START UP 2 When water is running steadily at the drain open the bypass valve s inlet and outlet to their maximum position 3 Simultaneously press the SET and...

Page 11: ...ss the SET button The screen will show the Day of Week in blinking triangle 2 To change the Day of Week use the UP or DOWN arrows 3 Press the SET button Time of Regeneration Setting the factory defaul...

Page 12: ...use the UP or DOWN arrows 3 Press the SET button Note The screen will now flash between flow rate and gallons remaining until next regeneration If water was tested by Master Water Conditioning follow...

Page 13: ...11...

Page 14: ...ual bypass valve Leak at riser pipe seal Insure that riser pipe is properly sealed at o ring seal Inspect pipe for cracks Insufficient brine Check brine float height and clean assembly if necessary Ch...

Page 15: ...o height of valve Damaged valve disk Replace all valve disks Partially restricted drain line Remove restriction Symptom Insufficient Refill to Brine Tank Possible Cause Solution Brine refill control R...

Page 16: ...ral bed with cleaner Slots in riser pipe or laterals are filled with resin fines Inspect and clean distributor pipe slots as needed Symptom Salt in Water to Service After Regeneration Possible Cause S...

Page 17: ...15...

Page 18: ...16...

Page 19: ...17...

Page 20: ...18...

Page 21: ...l be void in the event of damages from external sources or where the conditioner has been operated at pressure in excess of 100 pounds per square inch or at a temperature greater than 100 degrees F or...

Reviews: