Problem:
Leak to Drain
Possible Cause
Solution
No flow control installed in drain
line.
Install drain line flow control.
Insufficient water pressure.
Increase water pressure above 25
psig (172kPa) minimum.
Problem:
Loss of Water Pressure
Possible Cause
Solution
Fouled resin bed due to iron
accumulation.
Clean control valve and mineral bed
with cleaner.
Slots in riser pipe or laterals are
filled with resin fines.
Inspect and clean distributor pipe slots
as needed.
Problem:
Salt in Water to Service after Regeneration
Possible Cause
Solution
Injector is too small for system size. Install correct injector
Brine draw time excessively long
due to low water pressure.
Increase water pressure above 25
psig (172 kPa) minimum.
Restricted drain line.
Remove drain line restriction.
Insufficient rinse volume.
Increase slow rinse time, fast rinse
time, or both.
Plugged injector and/or injector
screen.
Inspect and clean injector and/or
injector screen.
Problem:
Timer does not display time of day
Possible Cause
Solution
AC Adapter unplugged
Connect power
No electric power at outlet
Repair outlet or use working outlet
Defective AC Adapter
Replace AC Adapter
Defective PC Board
Replace PC Board