6.4 External components (pumps, valves)
Use wiring diagram supplied to connect external components. If expansion card is used, use.
X3 terminals. Temperature probes connect directly to expansion card terminals J9 a J10.
7 Control and measurement
Heat pumps are equipped for control of different systems. It depends if standard unit is used, or
optional equipment is ordered. Please see possibilities in following tables.
7.1 Standard unit
Units with standard delivery.
heat
pump
type
main HC
(buffer)
mixing / pump
HC
DHW
control
solar
control**
AQ
yes
2/-(2)*
yes
yes
AM
yes
2/-(2)*
yes
yes
EM
yes
2/-(2)*
yes
yes
LM
yes
2/-(2)*
yes
yes
BA
yes
2/-(2)*
yes
yes
BA Inverter
yes
2/-(2)*
yes
yes
* if mixing is not used, pump could be used
**
-solar panel probe is not the part of delivery and it must be ordered separately (Pt1000)
-whes solar control is used, 1 pump circuit is lost
7.2 Optional „Expansion Card“
It is optional equipment. It must be ordered together with heat pump. Expansion card is
delivered like separated wall mounted box, including all probes and terminals.
heat
pump
type
main HC
(buffer)
mixing / pump
HC
DHW
control
solar
control**
AQ
yes
3/3(6)*
yes
yes
AM
yes
3/3(6)*
yes
yes
EM
yes
3/3(6)*
yes
yes
LM
yes
3/3(6)*
yes
yes
BA
yes
3/3(6)*
yes
yes
BA Inverter
yes
3/3(6)*
yes
yes
* if mixing is not used, pump could be used
**
-solar panel probe is not the part of delivery and it must be ordered separately (Pt1000)
-whes solar control is used, 1 pump circuit is lost
7.3 Probes connection
Each heating circuit requires temperature probe. Temperature probas are always part of
delivery. Please check wiring diagram supplied with the heat pump.