background image

11

DISPLAY PANEL OF FREEZER

9

TEMPERATURE

D.F.

8

7

6

5

4

3

2

1

FAN

DOOR

MANUAL DEFROST

TEMPERATURE

˚F

TEMP. SETTING

MANUAL DEFROST

INDICATOR

FAN RUNNING

INDICATOR

DOOR OPENING

INDICATOR

MANUAL DEFROST

BUTTON

TEMP. CONTROL BUTTON

(SEE TO PAGE 12~13)

INNER TEMP.

(SEE TO PAGE 14)

(SEE TO PAGE 12~13)

Summary of Contents for CCR-23SF

Page 1: ...6 16 TEL MODEL CCR 23SR 49DR 72TR WCC 23SR WCR 23SR CCR 23SF 49DF 72TF WCR 23SF BUYER 1 03 2 7 6 2 03 2 13 7 3 03 7 22 8 4 03 7 25 9 5 03 7 28 10 03 7 28 Han MEMO 03 12 15 3page 6 V VI IS SI IO ON N T...

Page 2: ...ation Manual Please read this manual completely before attempting to install or operate this equipment Full Stainless Steel Visible Exterior Refrigerator CCR 23SR CCR 49DR CCR 72TR WCC 23SR WCR 23SR F...

Page 3: ...er for service purpose SERIAL NUMBER Refrigerators SPECIFICATION MODEL COMP H P V Hz REFRIGERANT AMPS WEIGHT CCR 23SR 1 4 115V 60Hz R 134a 5 5A 265lbs CCR 49DR 1 3 115V 60Hz R 134a 9 2A 397lbs CCR 72T...

Page 4: ...NOT PLACE NEAR HEAT High ambient temperature will adversly affect cooling efficiency 3 INDOOR USAGE ONLY Be sure to install this unit indoors 4 STABILIZING While in use make sure the front wheels are...

Page 5: ...cleaned frequently to maintain proper sealing 4 CHECK AFTER CLEANING Check the unit again for safety Check that the unit is operating properly 1 POWER CORD Be sure that the power cord is connected to...

Page 6: ...3 C inside 3 Set toward Cool for higher temperature and Cold for lower temperature 4 The thermostat controls compressor s cycling by sensing inside temperature 5 Interior light is activated by the doo...

Page 7: ...setting is No 5 3 The compressor is automatically cycled by the electronic controller PCB D Sensor 4 The Defrost cycle is automatically controlled by the R sensor and the PCB 5 Set level toward 1 for...

Page 8: ...RATURE Q C 8 7 6 5 4 3 2 1 FAN DOOR QUICK COOLING TEMPERATURE F TEMP SETTING QUICK COOLING BUTTON TEMP CONTROL BUTTON SEE TO PAGE 8 INNER TEMP SEE TO PAGE 9 SEE TO PAGE 8 QUICK COOLING INDICATOR FAN R...

Page 9: ...in during Quick Cooling mode the compressor will return to the normal operation 3 During the Quick Cooling mode the temperature Up Down button will not affect the compressor s operation 1 By pushing t...

Page 10: ...ll three doors for CCR 72TR is closed 1 If any door is opened door opening indicator will be turned on 2 In case that any door was opened around 30 seconds warning beep sound will be ring three 3 time...

Page 11: ...oller PCB F Sensor 4 The Defrost cycle is automatically controlled by the D sensor and the PCB 5 Set toward 1 for higher temperatures and toward 9 for lower temperatures 6 The interior light is activa...

Page 12: ...F 8 7 6 5 4 3 2 1 FAN DOOR MANUAL DEFROST TEMPERATURE F TEMP SETTING MANUAL DEFROST INDICATOR FAN RUNNING INDICATOR DOOR OPENING INDICATOR MANUAL DEFROST BUTTON TEMP CONTROL BUTTON SEE TO PAGE 12 13...

Page 13: ...her level numbers 1 The electronic defrost controller is set at the factory to provide a defrost cycle every 6 hours 4 defrosts per day 2 If it is necessary to change the intervals of defrost due to u...

Page 14: ...the up or down button The temperature setting will be locked back automatically in five seconds after you set Factory setting is level 5 1 The electronic defrost controller is set at the factory to pr...

Page 15: ...rs for CCR 49DF all three doors for CCR 72TF is closed 1 If door is opened door opening indicator will be turned on 2 Passing the thirty seconds after the door is opened there will be a warning sound...

Page 16: ...BOTTOM HINGE 3POINTS 8 SUBSTITUTE THE POSITION OF LEFT GRILL FIXTURE AND RIGHT GRILL FIXTURE 9 USE BOLTS FOR FIXING THE TOP HINGE AT BOTTOM LEFT SIDE 10 SET UP THE DOOR AT THE TOP HINGE AFTER ROTATIN...

Page 17: ...16 INSTALLATION METHOD OF REVERSE DOOR...

Page 18: ...y The back side of the unit is too close to the wall The tray is not in the correct position High moisture air can produce dewdrops during rainy season The door is opened too frequently or left open l...

Page 19: ...SS OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE In no event shall the Company be liable for loss of use revenue or profit or for any other indire...

Page 20: ...the consignee with the carrier Master Bilt assumes no responsibility for damages while in transit 6 TAXES Federal state city sales or use taxes are not included with these prices 7 CANCELLATIONS Buyer...

Reviews: