13
1. If you push MANUAL DEFROST button for 5 seconds, the Defrost will start.
2. During the Manual Defrost mode, the Up/Down button for the temp. control can not
make the compressor cycle ON or OFF.
3. If you want to change the Manual Defrost mode in the normal mode, push MANUAL
DEFROST button for 5 seconds.
1. Keep pressing up&down buttons simultaneously for five seconds, then the lock will
be cancelled with beep sound.
* This unit has lock function that prevents unauthorized person from changing the
temperature setting
2. Set the temperature setting from level 1 to level 9 by pressing the up or down button.
* The temperature setting will be locked back automatically in five seconds after you
set.
* Factory setting is level 5.
1. The electronic defrost controller is set at the factory to provide a defrost cycle every 6
hours (4 defrosts per day).
2. If it is necessary to change the intervals of defrost due to unusual operating
conditions, it can be accomplished by adjusting the switch which is located on the
inside of the top grille.
3. Once all frost is eliminated, the temperature coil continues to rise until it reaches 60˚F
(15˚C). When this temperature is sensed by the defrost limit control, the defrost
control changes to refrigeration mode.
4. The panel displays “